SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
18KS52
KS1852/C1852
WALL MOUNTED AIR CONDITIONER
GENERAL DATA(AT 230V)
POWER V/PH/HZ
Circuit Ampacity, Min. (A)
Fuse size, Max.
(A)
COMPRESSOR
No. used
R.L. Amps - L.R. Amps (A)
Crankcase Heater
OUTDOOR FAN TYPE
Dia. (in.) - No. used
Type Drive - No. speeds
No. Poles - RPM (High)
No. Motors - W
CFM (High)
F.L. Amps. (A)
OUTDOOR COIL - TYPE
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
INDOOR FAN - TYPE
Dia. & Length (in.) - No. used
No. speeds
No. Poles -RPM (High)
No. Motors - W
CFM (HI/MED/LOW)
F.L. Amps (A)
INDOOR COIL - TYPE
Fin Type - Pipe type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (mm)
Drain Connection Size (in.)
REFRIGERANT
Lbs. - R22 (O.D. Unit)
Control Capillary
Connection
Line Length, Max (ft.)
Lift difference, Max (ft.)
Line Size - in. O.D. Discharge
Line Size - in. O.D. Suction
DIMENSIONS (in.)
Indoor Unit
-Uncrated 11-7/32 x 39-3/16 x 7-23/32
 
-Crated
10-7/8
Outdoor Unit -Uncrated 24-19/32 x 34-21/32 x 12-19/32
-Crated
27-15/16 x 40-9/16 x 16-3/16
 
WEIGHT
INDOOR
Net (lbs.)
26.5
Shipping (lbs.)
33.0
Shipping Volume(cu.ft.)
3.78
230/208 /1/ 60
15
15
Rotary-Hermetic
1
7.8/8.4-43
Propeller
16-17/32 - 1
Direct - 1
6 - 830
1 - 50
1,390
0.49/0.46
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 - 24
5.2
3/8
Cross-flow
3-15/32 & 29-3/8-1
3 & Auto
4-1,300
1 - 30
390/345/315
0.25/0.23
Alminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 - 18
2.64
7
23/32
R22
3.77
Tube
Flare
65
23
1/4
5/8
H
x
W
x
D
x 42-1/8
x 14-9/32
OUTDOOR
104
112
10.6
                   
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230V/208)
                              
COOLING
Total Capacity (BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity (BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (bels)
                                
 
FEATURE
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
(Horizontal)
(Vertical)
Power Failure Automatic Restart
OPTION
Refrigerant Line Set
Fresh Air Intake
Central Remote ON-OFF Control
Airduct Extension
Condensate Drain Pump
Non-Removable Remo-con Bracket
Air Clean Filter
Outdoor unit Mounting Bracket
OPERATING RANGE
Cooling
Indoor Air
 
Intake Temp.
Maximum
95 F DB/71 F WB
Minimum
67 F DB/57 F WB
CERTIFICATION
AIRCONDITIONING PRODUCTS
  SS-18KS52-3
17,000 / 16,500
12,200 / 11,950
4,800 / 4,550
10.4 / 10.4
4.4 / 4.3
7.8 / 8.4
1720 / 1670
7.8
Microprocessor
LCD Wireless type
IC Thermostat
Program Timer / 1 hour OFF
Built-In
Manual
Auto
Built-In
AP2507BH (20 ft)
AP2510BH (30 ft)
AP2515BH (50 ft)
N/A
Available
N/A
Available
Available
Available
Available
Outdoor Air
Intake Temp.
115 F DB
67 F DB
18KS52

Advertisement

loading

Summary of Contents for Sanyo 18KLS52

  • Page 1 SUBMITTAL SHEET SYSTEM INDOOR/OUTDOOR AIRCONDITIONING PRODUCTS 18KS52 KS1852/C1852 WALL MOUNTED AIR CONDITIONER                       SS-18KS52-3 PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230V/208) GENERAL DATA(AT 230V)                                COOLING POWER V/PH/HZ 230/208 /1/ 60 Total Capacity (BTU/H) 17,000 / 16,500 Circuit Ampacity, Min. (A) Sensible Capacity (BTU/H) 12,200 / 11,950 Fuse size, Max.
  • Page 2 AIRCONDITIONING PRODUCTS INDOOR/OUTDOOR 18K L L L L S52 KS1852/C L L L L 1852 WALL MOUNTED LOW AMBIENT AIR CONDITIONER                       SS-18KLS52-3 GENERAL DATA(AT 230V) PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)                                POWER V/PH/HZ 230/208 /1/ 60 COOLING Circuit Ampacity, Min.

This manual is also suitable for:

18ks52Ks1852C1852Cl1852