The appliance must be placed at a location whose
ambient temperature corresponds to the climate
classification*, for which the appliance is designed.
* See on the rating plate on the inside of the
appliance.
The following table shows which ambient
temperature is correct for each climate classification.
Climate
for an ambient temperature of
classification
SN
N
ST
T
Check that the drain hose at the rear of the appliance
discharges into the drip tray.
If the appliance is placed in a corner and the side
with the hinges facing the wall, the distance between
the wall and the appliance must be at least 10 mm to
allow the door to open enough so that the shelves
can be removed.

Electrical connection

Any electrical work required to install this
appliance should be carried out by a
qualified electrician or competent person.
This appliance must be earthed.
The manufacturer declines any liability should
these safety measures not be observed.
Electrical Requirements
Before switching on, make sure the electricity
supply voltage is the same as that indicated on the
appliance rating plate.
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1362) fuse
must be used.
Should the plug need to be replaced for any reason.
The wires in the mains lead are coloured in
accordance with the following code:
Green and yellow
-Earth
Blue
-Neutral
Brown
-Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter "E"
or by the earth symbol
yellow.
The wire coloured blue must be connected to the
terminal marked "N" or coloured black
+10°C to +32°C
+16°C to +32°C
+18°C to +38°C
+18°C to +43°C
or coloured green and
a)
The power plug must be accessible after installation
of the appliance.
The wire coloured brown must be connected to the
terminal marked "L" or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.