Master-Bilt Electronic Refrigeration Control - Master Bilt TAF-27 Installation & Operation Manual

Solid door reach-in freezers with dixell controller
Hide thumbs Also See for TAF-27:
Table of Contents

Advertisement

MASTER-BILT ELECTRONIC REFRIGERATION CONTROL

OPERATION
Compressor When power is first turned on to the control, the LED indicator under COMP on the
display starts blinking. After one-minute delay the compressor comes on. The COMP LED indicator
stays on while compressor relay is energized. Display will show actual box temperature. Figure 4 is
the display layout.
The compressor will be cycled off when the actual box temperature reaches its set point. The
COMP indicator will be off.
Fig. 4 – Display Lay-out
Fan
The fans will run constantly except when a defrost is initiated, or when the evaporator temp
o
is above the 30
F. When in defrost mode the fan is off until the end of the defrost and the 2 minute
drip time has passed. There is 4 minutes delay after a defrost before the fan comes on. The
difference of the evaporator and room temperature of more than 9
FAN LED indicator is on while FAN relay is energized.
Defrost
The control uses demand defrost with at least one defrost per day for oil return
safety. The control can be used for scheduled defrost. A programmed "HOT-KEY" has to be used to
re-set the defrost scheme for special applications. During defrost the display will show dEF and the
LED indicator under DEF in on.
MANUAL DEFROST
1. Push this DEFROST
2. While in defrost, Push and hold the DEFROST
the controller will end the defrost cycle. The controller will then enter drip mode for 2
minutes. The DEF led is flashing in drip mode.
HOW TO SEE THE SETPOINT(Box temperature cut-out)
1.
point value;
2. Push and immediately release the SET key or wait for 5 seconds to display the probe value
(actual box temperature) again.
HOW TO CHANGE THE SETPOINT
key for more than 2 seconds and a manual defrost will start.
Push and immediately release the SET key: the display will show the Set
o
key for more than 5 seconds and
9
F will override the fan delay.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taf-48Taf-74

Table of Contents