Adjustment Of The Oven Burner Minimum; Lubrication Of The Gas Taps - Zanussi Z 9060WOS Instructions For Use And Installation Instructions

Cookers z 9060wos; z 9060 xos
Table of Contents

Advertisement

ADJUSTMENT OF THE OVEN
BURNER MINIMUM
This needs to be done only for the oven
burner (the grill is a fixed capacity) by
acting on the thermostat in the following
way:
– turn on the burner by setting the ther-
mostat knob on position 10
– unscrew the by-pass screw (fig. 8.13)
about three times by a flat screwdriver
– let the oven heat up for about 10 min-
utes, then bring the thermostat to posi-
tion 1 (minimum) to operate the ther-
mostat by-pass
– slowly screw the by-pass screws "G"
(fig. 8.13) until you obtain a flame of 3-
4 mm in height.
N.B. For G30/G31 the by-pass screw
must be fixed thoroughly.
G
Fig. 8.13
IMPORTANT
All interventioni regarding instal-
lation maintenance and conver-
sion of the appliance must be
fulfilled with original factory
parts.
The manufacturer declines any
liability resulting from the non-
compliance of this obligation.
Flame correct
Flame faulty in
primary air
Flame with excess
primary air

LUBRICATION OF THE GAS TAPS

If the gas taps are not working correctly,
call the After-Sales Service.