HEAT PUMP AND TANK ASSEMBLY
8.
Cover Strip: (410 litre storage tank only) – Retrieve the length of rubber cover strip from the kit supplied
with the 410 storage tank.
Line up one end of the cover strip with one end of the heat pump housing black top, fitting the strip
over the lip of the housing, ensuring the jacket is hard up against the lip of the heat pump housing.
The cover strip will hold the jacket in position.
Apply the cover strip along the full length of the lip of the heat pump housing.
9.
Heat Pump Module Cover: Remove the two screws securing the module cover to the heat pump
module.
Remove the module cover from the heat pump module.
remove module cover from heat pump module and feed through cables
10.
Position Heat Pump Module: Position the edge of the heat pump module which is closest to the wall
against the storage tank so the screw holes in the module are adjacent to the nutserts in the storage
tank.
11.
Power Cable and Tank Sensor Cable: Feed the power cable from the lower front cover and tank
sensor cable through the heat pump module so they protrude out of the front of the module.
Step 8 – apply cover strip to heat pump housing
Steps 9 and 11