Instructions For The Installer - Zanussi Electrolux ZGF 98 Instruction Book

Table of Contents

Advertisement

Instructions for the Installer

Engineers technical data
OVERALL DIMENSIONS
Width:
860 mm
Depth:
510 mm
CUT OUT DIMENSIONS
Width:
830 mm
Depth:
480 mm
SUPPLY CONNECTIONS
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
220 V 50 Hz supply, 3 core flexible cable with non
rewireable plug.
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Ultra-rapid
56
Aeration adjustment none
BURNER
RAPID
(large)
POSITION
MAX
kW
3.0
3
m
/h
0.286
0.062
119
Adjust.
1/100 mm
kW
2.8
g/h
202
86
1/100 mm
Rear Left Burner (semi rapid)
Heat Input
Front Left Burner (auxiliary)
Heat Input
Rear Right Burner (semi rapid)
Heat Input
Front Right Burner (rapid)
Heat Input
Central Burner (Ultra-rapid Triple-crown)
Heat Input
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
2.0
0.45
1.0
0.190
0.043
0.095
96
Adjust.
70
0.65
2.0
0.45
1.0
47
144
32
72
40
71
32
50
APPLIANCE CLASS : 3
APPLIANCE GAS SUPPLY: gas G28-30 / 37mbar
2.0 kW
1.0 kW
2.0 kW
3.0 kW
4.0 kW
ULTRA-RAPID
(small)
(triple-crown)
MIN
MAX
MIN
0.33
4.0
1.2
0.031
0.381
0.114
Adjust.
146
Adjust.
0.33
4.0
1.2
24
288
86
28
98
56
17

Advertisement