    2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of- life, should be disposed of separately from your household waste.
  • Page 3 2. Parts Names Wired Remote-Controller “Sensor” indicator Display Section Displayed when the remote controller sensor is used. Day-of-Week For purposes of this explanation, all parts of the display are shown Shows the current day of the week. as lit. During actual operation, only the relevant items will be Time/Timer Display displayed.
  • Page 4 2. Parts Names Wireless Remote-Controller Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset button is pressed. Operation areas ON/OFF button Temperature set buttons...
  • Page 5: Screen Configuration

    3. Screen Configuration <Screen Types> For details on setting the language for the remote controller display, refer Function Selection of remote controller Set Day/Time to section 8. Function Selection. TIME SUN The initial language setting is English. Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.)
  • Page 6 5. Operation <To Stop Operation> 5.4. Fan speed setting Press the ON/OFF button 1 again. Press the Fan Speed button 5 as many times as necessary while the • The ON lamp 1 and the display area go dark. system is running. •...
  • Page 7 5. Operation 5.5. Airflow up/down direction setting 5.6. Ventillation <To change the airflow up/down direction> For LOSSNAY combination 5.6.1. For Wired Remote-controller With the unit running, press the Airflow up/down button 6 as necessary. To run the ventilator together with the indoor unit: •...
  • Page 8: Timer

    6. Timer 6.1. For Wired Remote-controller <How to Set the Weekly Timer> 1. Be sure that you are at a standard control screen, and that the weekly You can use Function Selection of remote controller to select which of timer indicator 1 is shown in the display. three types of timer to use: 1 Weekly timer, 2 Simple timer, or 3 Auto 2.
  • Page 9 6. Timer 6.1.2. Simple Timer 7. Press the appropriate Temperature set button 3 to set the desired temperature (at 7). You can set the simple timer in any of three ways. • Start time only: * Each press changes the setting, in the following sequence: No display (no setting) ⇔...
  • Page 10 6. Timer Example 2: 7. After completing steps 3 to 6 above, press the Filter button 4 to Start the timer, with OFF time is sooner than ON time lock in the value. ON Setting: 5 hours Note: Your new settings will be cancelled if you press the Operation mode (Back) OFF Setting: 2 hours button 2 before pressing the Filter button 4.
  • Page 11: Other Functions

    6. Timer <Checking the Current Auto Off Timer Setting> 6.2. For wireless remote controller Timer Setting TIMER AFTER AUTO OFF 1. Be sure that the “Auto Off” is visible on the screen (at 1). 2. Hold down the Timer Menu button b for 3 seconds, so that “Monitor” is indicated on the screen (at 4).
  • Page 12: Function Selection

    7. Other Functions 7.2. Error Codes indication ERROR CODE ON lamp ON/OFF (Flashing) Error Code Indoor Unit No. Indoor Unit’s Refrigerant Address Alternating Display If you have entered contact number to be called in the event of a problem, the screen displays this number. (You can set this up under Function Selection of remote controller.
  • Page 13 8. Function Selection Normal display [Function selection flowchart] (Display when the air condition is not running) Setting language (English) Hold down the E button and press the D button for 2 seconds. E Press the operation mode button. Hold down the E button and press the D button for 2 seconds. G Press the TIMER MENU button.
  • Page 14 8. Function Selection [Detailed setting] [4]–3. Operation mode selection setting (1) Remote controller main/sub setting [4]–1. CHANGE LANGUAGE setting • To switch the setting, press the [ ON/OFF] button D. The language that appears on the dot display can be selected. 1 Main: The controller will be the main controller.
  • Page 15 8. Function Selection [Dot display table] Selecting language English Germany Spanish Russian Italy Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 16: Emergency Operation For Wireless Remote-Controller

    9. Emergency Operation for Wireless Remote-controller [Combination Cooling and Heating Models] PKA-RP·KAL Cooling Heating Stop [Cooling Only Models] Cooling Stop Operation Monitor Display GREEN ORANGE The display will appear orange for 5 STOP seconds following the switch operation COOL as indicated at the left, and then it will HEAT return to the regular display.
  • Page 17: Troubleshooting

    11. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit.
  • Page 18: Specifications

    11. Troubleshooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.