Download Print this page

Flow Chart - Kenwood KSC-35S Service Manual

Rapid charger

Advertisement

• About voltage write down,
VB = (B1 + voltage) – Vf (Vf ≈ 0.25Vdc)
Therefore battery voltage must consider
Vf of protected reverse connection diode.
• Battery voltage should be kept inspecting
when charge condition and on tempera-
ture stand-by condition.
A1
T 0°C
Timer stop
or
0°C T 40°C
T 40°C
Stand-by temperature
timer 30min. start
LED: Red
A2
T 0°C
Timer
or
recount
T 57°C
0°C T 45°C
Stand-by temperature
timer hold
LED: Red

FLOW CHART

START
No
Does T
contact?
Yes
Yes
open/short
check
No
Passage 30min.
A1
Give all B+ terminal power
60mA, 5 second
Voltage
and open/short
check
Below 6.1V
Voltage
check
90min. timer stop
Rapid charge
Constant charge current
850mA
Constant charge voltage
8.65V
210min. timer start
LED: Red
Charge current is
100mA±20mA
or passage
210min.
Detected full charge
Finish charge
210min. timer stop
LED: Green
Below 7.6V
Above 8.55V or Below 1.8V
Low voltage battery
charge: 150mA
90min. timer start
LED: Red
Above 6.1V
A2
When rapid charge start
passage 10min.
Below 7.5V
Above 8.85V or Below 5.5V
Above 8.55V
KSC-35S
Error battery
LED: Red Flash
Go to START
when T contact is off.
Temperature error
battery
LED: Green
and Red Flash
when T contact is off.
Passage
90min.
Error battery
timer stop
LED: Red Flash
Go to START
when T contact is off.