2.3 Installation Site Preparation

You can mount POE-FSH8PW either on desktop or on a 19-inch rack. If you plan to mount
the switch on desktop, please choose a steady, level surface in a well-ventilated area that
is free from excessive dust. In any case, the installation site chosen for your switch has to
comply with the following requirements:
The surface where you want to mount the switch must be able to sustain at least 1.5kg.
Do not place heavy objects (more than 3kg) on top of the switch.
The location must preferably be free from excessive dust, away from heat vent, hot-air
exhaust and direct sunlight.
The switch should not be placed near large electric motors or other strong
electromagnetic sources. As a reference, the strength of the electromagnetic field on
site should not exceed the (RFC) standards for IEC 801-3, Level 2(3V/M) field strength.
The air temperature in the location should be within a range of 0 to 65°C.
The relative humidity in the location should not exceed 90% non-condensing humidity.
The distance between the RJ-45 port and the standard network interface should not
exceed 100 meters.
Adequate space should be allowed in front of all the ports, so that each port is easily
accessible for cable connections.
Leave at least 10cm(4 inch) of space around the switch to allow heating dissipation
AirLive POE-FSH8PW User's Manual