Power Supply is dual rated: 240 Volts or 208 Volts, 3 wire, 60 Hz, with the following circuit breaker requirements: Model CEM304 at 30 Amps; Model CEM365 at 40 Amps or Model CEM456 at 50 Amps Install a junction box (not supplied), below the counter top within 3 feet of flexible conduit (supplied) located at the right rear corner of the cooktop rough-in box.
Installation Instructions Models: CEM304, CEM365, CEM456 CABINET PREPARATION AND COUNTERTOP CUTOUT DIMENSIONS CLEARANCES The cutout dimensions depend upon whether the To eliminate the risk of burns or fire by reaching over installation is for replacement, new construction, or heated surface units, cabinet storage space located installation in a solid surface countertop material, such above the surface units should be avoided.
C301, CM 301 (Optional) I , J , K , and L . ® The cooktop can be installed over a single Thermador electric oven. The cooktop should be located on the same center line as the under-the-counter single oven.
Installation Instructions Models: CEM304, CEM365, CEM456 BEFORE CALLING FOR SERVICE If the elements do not heat or if the indicator “on” light does not glow, check the power source to see if a fuse has blown or if the circuit breaker has tripped.
Page 8
Thermador indicating the model number. We reserve the right to change specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer.