Optional Accessories - Williams 6008532 Owner's Manual

Magnum forsaire counterflow top-vent gas wall furnace
Hide thumbs Also See for 6008532:
Table of Contents

Advertisement

Introduction

Optional Accessories

SIDE OUTLET REGISTER 6701 Pg. 21
Let's you route some heated air to a second room. Mounts on side
wall of second room and must be within 10 inches of wall furnace.
DIFFUSER GRILLE KIT 6703 as shown on Page 23, Fig. 32
Let's you route some heated air in a two-way direction. Kit 6704
for one-way direction.
REAR OUTLET KIT 6801
Let's you route some heated air to a second room behind the
furnace. Finished wall of second room must be within 10 inches of
furnace as shown on Page 8, Fig. D. Built-in damper lets you shut
off air flow to second room if desired.
SHORT REAR OUTLET KIT 6802
Let's you route some heated air to a second room behind the
furnace when furnace is recessed mounted. Built-in damper lets
you control the air flow to the second room.
TRIM STRIP KIT 4701
Provides finished edge at sides of wall furnace. Neutral beige
enamel painted steel.
Unpack Your Furnace
The furnace is shipped in one carton containing the furnace,
installation instruction booklet and hardware bag.
1. Lay carton horizontally. Open carton and remove top trim
cover from its packing. Remove thumb screw at top of
furnace, raise top front panel ½ inch and remove panel from
cabinet. This is so you can get to the electrical connections
later.
2. Place these and other parts, as they are removed from
furnace, where they cannot be lost or damaged before you
need them.
3. Bottom front panel can be removed by grasping just below
handle and pulling it outward and then upward. See Fig. 1.
NOTE
Check the burner rating plate, located in burner compartment, to
make sure your furnace is equipped to operate on the type of gas
available (either Natural or L.P. Gas). Do NOT convert unit from
Natural Gas to L.P. Gas or from L.P. Gas to Natural
4. Remove all literature and package containing thermostat, wire
and metal anchors used for free standing installation.
5. Check the fan blade to be sure it spins freely.
6
OVAL VENT KIT 9901
This U.L. listed B/W vent kit contains 4 feet of oval double walled
vent pipe, plate spacers and starter or hold-down plate that starts
the venting from the top of the furnace. See page 16 for additional
items you will need.
VENT ENCLOSURE KITS 9812 or 9824
These kits are used only when the furnace is surface mounted.
They enclose the vent pipe from the top of the surface to the
ceiling.
SIDE OUTLET GRILLE KIT 6702 as shown on Page 22, Fig. 31
Allows you to direct heated air from the side of furnace into the
same room.
NOTE.
AII kits are identified on the carton by their Manufacturing Number
respectively, 6701, 6703, 6704, 6801, 6802, 4701, 9901, 9812,
9824 and 6702. These numbers are also listed on the furnace
rating plate.
FIGURE 1