9-7. Test point diagram and voltage
1. Indoor power P.C. board, Indoor terminal P.C. board
Indoor terminal P.C. board
Fuse (F11)( )
Terminal
block
Connector to indoor electronic
control P.C. board (CN20A)
Please replace the fuse after removing the indoor terminal P.C. board from the electrical box.
2. Indoor electronic control P.C. board
Timer short mode point JPG JPS
(Refer to 7-1.)
Emergency operation
switch (E.O.SW) (SW1)
Indoor power P.C. board
Varistor (NR11)
12 VDC
5 VDC
Room temperature thermistor RT11 (CN111)
Indoor coil thermistor RT12, RT13 (CN112)
GND
Vane motor (CN151)
Connector to
Indoor power P.C. board
(CN10A)
5 VDC
Release of Auto restart function
Solder the Jumper wire to JR07
(Refer to 7-3.)
Resistor (R111)
GND
12 VDC
27
Indoor fan motor
(CN211)
294/325 VDC
(–) GND (high-
voltage DC)
15 VDC
(+)3-6 VDC
(+)0-6 V
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
32 50 68 86 104 122 140
Temperature (°F)