General Operating Instructions
1. Before each use, test the tool as
directed in the prior section.
2. If an automatic oiler is not used, add a few
drops of Pneumatic Tool Oil to the airline
connection before use. Add a few drops
more after each hour of continual use.
3. Shingle Guide Setup:
The Shingle Guide (79) controls roof shingle spacing.
a. Use the Hex Wrench to loosen the
Screw (80) on the Shingle Guide.
b. Slide the Guide to the desired spacing.
c. Then, retighten the Screw.
SHINGLE SPACING
(bottom view)
WARNING! TO PREVENT
SERIOUS INJURY: Keep second hand
away from tool discharge area,
especially if holding workpiece.
Tool applies extreme force to fastener,
and fasteners may deflect or fire in an
unexpected direction.
4. To fire, place the nose of the Nailer on the
workpiece and push down until it stops.
Pull the Trigger to fire a nail.
Item 67450
Shingle
Screw
Guide
(80)
(79)
For technical questions, please call 1-800-444-3353.
5. If the tool requires more force to accomplish
the task, verify that the tool receives sufficient,
unobstructed airflow (CFM) and increase the
pressure (PSI) output of the regulator up to the
maximum air pressure rating of this tool. The
adjuster can also be used to correct the firing depth.
CAUTION! TO PREVENT INJURY FROM TOOL OR
ACCESSORY FAILURE:
Do not exceed the tool's
maximum air pressure rating.
If the tool still does not have sufficient force
at maximum pressure and sufficient airflow,
then a larger tool may be required.
6. After use, to prevent accidents:
a. Release the trigger.
b. Detach the air supply.
c. Attempt to fire the Tool into a piece of scrap
wood to ensure that it is disconnected
and is incapable of firing any fasteners.
d. Release the trigger again.
e. Clean external surfaces with clean, dry cloth.
f. TAR BUILDUP:
Use kerosene or diesel fuel to remove
tar buildup. DO NOT USE GASOLINE.
The front of the nailer can be submerged
in solvent only up to the nail head height.
To prevent o-ring damage,
do not allow solvent to get into the cylinder.
g. Carefully dry off all solvent before next use.
Any solvent left on the nailer will cause it to
accumulate tar buildup much more quickly.
h. Store indoors out of children's reach.