Sharp EL-546LV Operation Manual

Scientific calculator

Advertisement

SCIENTIFIC CALCULATOR
OPERATION MANUAL
INTRODUCTION
After reading this manual, store it in a convenient location for future
reference.
Operational Notes
To ensure trouble-free operation, observe the following points:
1. Do not carry the calculator in the back pocket of slacks or
trousers.
2. Do not subject the calculator to extreme temperatures.
3. Do not drop it or apply excessive force.
4. Clean only with a soft, dry cloth.
5. Do not use or store the calculator where fluids can splash onto it.
SHARP will not be liable nor responsible for any incidental or
consequential economic or property damage caused by misuse
and/or malfunctions of this product and its peripherals, unless
such liability is acknowledged by law.
♦ Press the RESET switch only in the following cases:
• When using for the first time
• After replacing the batteries
• To clear all memory contents
• When an abnormal condition occurs and all keys are inopera-
tive.
If service should be required on this calculator, use only a SHARP
servicing dealer, SHARP approved service facility, or SHARP re-
pair service where available.
Hard Case
DISPLAY
Equation
Display
Mantissa
(All symbols will not be displayed simultaneously, as shown above.)
: Appears when the entire equation cannot be displayed.
/
Press </> to see the remaining (hidden) section.
: Indicates the mode of expression of results in the com-
xy/r
plex calculation mode.
: Appears when @ is pressed, indicating that the func-
2ndF
tions shown in orange are enabled.
: Indicates that h has been pressed, and the hyper-
HYP
bolic functions are enabled. If @H are pressed,
the symbols "2ndF HYP" should appear, indicating that
inverse hyperbolic functions are enabled.
ALPHA : Indicates that @ K or O (R) has been
pressed, and entry (recalling) of memory contents and
recalling of statistics can be performed.
FIX/SCI/ENG: Indicates the notation used to display a value and
changes each time @ f are pressed.
DEG/RAD/GRAD: Indicates angular units and changes each time
G is pressed.
: Appears when a simulation calculation is executed.
ALGB
M
: Indicates that a numerical value is stored in the inde-
pendent memory.
Æ
: Indicates the operation mode.
?
: Indicates that the calculator waits for a numerical value
entry, such as during simulation calculation.
: Appears when the calculator shows an angle as the
result in the complex calculation mode.
: Indicates an imaginary number is being displayed in the
i
complex calculation mode.
ENGLISH
EL-546LV
MODEL
PRINTED IN CHINA
02LGK (TINSE0587EHZZ)
Symbol
Exponent
BEFORE USING THE CALCULATOR
Key Notation Used in this Manual
In this manual, key operations are described as follows:
x
e
To specify
To specify E (HEX) : E
In
To specify ln
To specify X
To access functions printed in orange above the key, press @
first.
Numbers are not shown as keys, but as ordinary numbers.
Power On and Off
Press N to turn the calculator on, and @ F to turn it off.
Clearing Methods
There are three clearing methods as follows:
Clearing
Entry
operation
(Display)
N
@c
RESET
: Clear
: Retain
*
1
Independent memory M.
2
*
Temporary memories A-D, X and Y, statistical data, and last an-
swer memory.
Refer to the Memory Calculations section.
Editing the Equation
• Press < or > to move the cursor.
To return to the equation after getting an answer, press @
'.
• To delete a number, move the cursor to the number to be
deleted, then press d.
The number under the cursor will be deleted.
• To insert a number, move the cursor to the place immediately
after where the number is to be inserted, then enter the number.
Priority Levels in Calculation
This calculator performs operations according to the following pri-
ority:
Q
W Functions preceded by their argument (x
¿
E Y
x
x
,
R Implied multiplication of a memory value (2Y, etc.)
T Functions followed by their argument (sin, cos, etc.)
Y Implied multiplication of a function (2sin30, etc.)
U
C
,
P
n
r
n
r
I , ÷
O +, –
P AND
{ OR, XOR, XNOR
M, |DEG, |RAD, |GRAD, DATA, CD,
} =, M+, M–,
and other calculation ending instruction
• If parentheses are used, parenthesized calculations have prec-
edence over any other calculations.
INITIAL SETUP
Mode Selection
Normal mode: m0
Used to perform arithmetic operations and function calculations.
The pointer "Æ" appears below "0: NORMAL".
Complex number mode: m1
Used to perform arithmetic operations with complex numbers.
The pointer "Æ" appears below "1: CPLX".
3-VLE mode : m2
Used to perform simultaneous linear equations with three unknowns.
The pointer "Æ" appears below "2: 3-VLE".
Statistic mode: m3
Used to perform statistical calculations.
The pointer "Æ" appears below "3: STAT".
When executing mode selection, temporary memories, statistical
data and last answer memory will be cleared even when reselecting
the same mode.
: @e
: I
: @KX
M*
1
A-D, X,Y*
STAT, ANS
-1
2
, x
, n!, etc.)
2
r ,
xy

Advertisement

Table of Contents
loading

Summary of Contents for Sharp EL-546LV

  • Page 1 Temporary memories A-D, X and Y, statistical data, and last an- tive. swer memory. Refer to the Memory Calculations section. If service should be required on this calculator, use only a SHARP servicing dealer, SHARP approved service facility, or SHARP re- pair service where available. Editing the Equation •...
  • Page 2: Scientific Calculations

    Selecting the Display Notation and Decimal Places • The calculator has four display notation systems for displaying 5 @Q 2 = calculation results. When FIX, SCI, or ENG symbol is displayed, 500 * 25 % 125. 500 25%= the number of decimal places can be set to any value between 0 and 9.
  • Page 3 • • • • • 24 = 2.4...(A) @ì 1FF @î+ 512 = 1511. 24 /( 4 + 6 )= HEX(1FF)+ @ì 3 *@?+ 60 / OCT(512)= 349. 3 (A)+60÷(A)= 32.2 HEX(?) NOM@ì 2FEC 2FEC– * Entry of the multiplication procedure is omitted between " " and - 2C9E ;...
  • Page 4: Metric Conversions

    Modify Function Constant Symbol Unit In this calculator, all calculation results are internally obtained in Boltzmann constant –1 J•K scientific notation with up to 12 digits for the mantissa. –1 Magnetic permeability µ H•m However, since calculation results are displayed in the form desig- –1 Dielectric permittivity F•m...
  • Page 5: Complex Number Calculations

    COMPLEX NUMBER CALCULATIONS x + y – z = 9 1 ® 1 ® 1 ±® 9 ® To carry out addition, subtraction, multiplication, and division using 6x+6y – z =17 6 ® 6 ® 1 ±® 17 ® complex numbers, press m1 to select the complex number 14x–7y+2z =42 14 ®...
  • Page 6: Single Variable Statistical Calculations

    Entered data are kept in memory until @ c or m 3 Statistical Calculation Formulas are pressed. Before entering new data, clear the memory contents. Type Regression formula [Data Entry] Linear y = a + bx Single-variable data Exponential y = a • e Data k Logarithmic y = a + b •...
  • Page 7: Error And Calculation Ranges

    ERROR AND CALCULATION RANGES Function Dynamic range Errors | x |, | y | < 10 An error will occur if an operation exceeds the calculation ranges, x, y | – |, x < 10 or if a mathematically illegal operation is attempted. When an error occurs, pressing <...
  • Page 8: Replacement Procedure

    Replacement Procedure 1. Turn the power off by pressing @ F. 2. Remove two battery cover screws. 3. Slide the battery cover slightly and lift it to remove. 4. Remove the used batteries by prying them with a ball-point pen or other similar pointed device.

Table of Contents