Download Print this page

American Standard Ceramix 2000.10X Installation Instructions Manual page 4

American standard centerset lavatory faucet installation instructions

Advertisement

10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
11
SERVICE
HOT LIMIT SAFETY STOP
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucets, all you need
to do is adjust the setting on the HOT LIMIT SAFETY STOP .
Remove necessary trim parts. Use a flat blade screwdriver or
pull forward with your fingers to rotate red HOT LIMIT SAFETY
STOP . Follow Step "A" or "B" to adjust max./min. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting.
POINTER ON
HOT LIMIT STOP
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Tighten
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
4
2
IF FAUCET DRIPS
If faucet drips, operate handle several times from
"off" to "on". Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow
in "full on" hot or cold. To clean inlets, first turn off
water supply, then:
Remove HANDLE (1), CAP (2), SCREWS (3) and
CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1).
Check flow.
"A"
5
RED RING HOT
LIMIT SAFETY
STOP
4
5
WASTE
OUTLET
"P" TRAP
1
3
2
4
M 9 6 8 7 6 0 R e v . 1 . 3  
1
3
2

Advertisement

loading

This manual is also suitable for:

Ceramix 2000.16xReliant 3 7385 seriesSeva 1480 series