Intel RAID
Intel RAID

Degraded RAID Array

A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard drive
members fails or is temporarily disconnected, and data mirroring is lost. As a result, the
system can only utilize the remaining functional hard drive member. To re-establish
data mirroring and restore data redundancy, refer to the procedure below that corre-
sponds to the current situation.
Missing Hard Drive Member
1.
Make sure the system is powered off.
2.
Reconnect the hard drive.
3.
Reboot the system to Windows; the rebuild will occur automatically.
Failed Hard Drive Member
1.
Make sure the system is powered off.
2.
Replace the failed hard drive with a new one that is of equal or greater capacity.
3.
Reboot the system to Intel RAID Option ROM by press <Ctrl> and <I> keys simul-
taneously during the Power-On Self Test (POST).
4.
Select the port of the destination disk for rebuilding, and then press ENTER.