Gas Connection - Miele KM 360 G Installation Instructions Manual

Gas hobs
Table of Contents

Advertisement

Connection to the gas supply, or
conversion from one type of gas to
another should only be undertaken
by an approved and registered gas
installer in strict accordance with
local and national safety and
building regulations, (e.g. Corgi
registered in the U.K.) Every
appliance should have its own
isolating valve and test point.
Check with your local gas supplier
about the type of gas and its
calorific value, and compare this
information with the type of gas
quoted on the hob data plate.
The installer is responsible for
ensuring that the appliance
functions correctly when installed.
This gas hob is normally suitable for
connection to either natural or liquid
gas. Check suitability in your country
with your dealer or agent.
United Kingdom:
GB II 2 H 3+ 20 mbar, 28-30/37 mbar
Ireland:
IE II 2 H 3+ 20 mbar, 28-30/37 mbar
The hob is supplied ready for
connection to natural gas.
Depending on country a set of jets for
conversion to liquid gas may be
included with the hob.

Gas Connection

Connection
Conversion to another type of gas is
described under the relevant Section.
The gas connection must be installed
so that connection can be made either
from inside or outside the kitchen unit,
and the isolating valve must be easily
accessible and visible (by opening one
of the kitchen unit doors, if necessary).
A test for possible leakages must be
carried out after installation.
Safety regulations demand that a
pressure test point is installed near a
gas hob to allow an engineer to test the
pressure, following servicing.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km 363 gKm 361 gKm 360-1 gKm 362 gKm 362-1 g

Table of Contents