Mechanical Description - Hamilton Sundstrand Company Gas Fuel Metering Valve HFG2.0 User Manual

Gas fuel metering valve
Table of Contents

Advertisement

2.3 Mechanical Description

Actuator
Main Housing Assembly
Brushless DC Motor Assembly
Motor Stator
30
Note: The MCE analog and discrete signal interfaces are
electrically isolated. The serial communication interface is
optically isolated
The HFG2.0 consists of two main parts, an actuator and a valve
assembly.
The actuator is the primary drive mechanism for the valve assembly. The
actuator portion of the HFG2.0 consists of four main assemblies:
Main Housing Assembly
Brushless DC Motor Assembly
Resolver Assembly
Linear Drive Mechanism
The main housing assembly consists of the main housing, motor cover,
extension-rod bearing, and associated seals. The main housing assembly
is the primary structural system component and supports all the bearings,
motor cover, mountings, and connectors. It also provides explosion-proof
containment.
The housing is fitted with a stainless steel liner to provide thermal and
dimensional stability for the main bearing. This liner is permanently
installed into the aluminum main housing. A retaining ring is included for
redundant retention.
The main housing also contains rigid mechanical stops to prevent
extension rod travel beyond the design specification. See Figure 2-2.
A brushless DC motor powers the HFG2.0 linear drive mechanism. The
DC motor consists of a stator and rotor. See Figure 2-2.
The motor stator is attached to the main housing by a pre-loaded wave
spring and screws. Thermistors are embedded in the stator windings to
HFG2.0 USER GUIDE

Hide quick links:

Advertisement

Table of Contents
loading