Simple Wired Remote Controller

Owner's & Installation Manual
Models: PQRCFCS0
Visit us at : http://www.lgservice.com
IMPORTANT
• Please read this installation manual completely
before installing the product.
• Installation work must be performed in
accordance with the national wiring standards
by authorized personnel only.
• Please retain this installation manual for future
reference after reading it thoroughly.
LG

Advertisement

Table of Contents
loading

Summary of Contents for LG PQRCFCS0

  • Page 1: Simple Wired Remote Controller

    Visit us at : http://www.lgservice.com Simple Wired Remote Controller Owner's & Installation Manual Models: PQRCFCS0 IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
  • Page 2: Table Of Contents

    Simple Wired Remote Controller Owner’s & Installation Manual TABLE OF CONTENTS I Safety Precautions..............3~4 I Part Description ..............5~6 I Installation Method ..............7 I Necessary functions before using .........8~10 • Trial Operation ..................8 • Setting the Central Control Address ............9 • ESP Function ..................10 I How to use the Mode Selection Button......11~17 •...
  • Page 3: Safety Precautions

    • The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company. • For all the problems arising after installation by someone who has no relevant qualifications, LG will not provide free service.
  • Page 4 Safety Precautions I In-use Do not modify or lengthen the Do not place a heating device Do not drop water on to the power cable at your discretion. near the product. It may cause product. It may cause an electric It may cause fire or an electric fire.
  • Page 5: Part Description

    Part Description Part Description 1. Wired Remote Controller PQRCFCS0 Defrost Preheat Out door 2. LCD Screen Room Temp Total on Central Run 3. Connecting Cable and Connector Cooling Heating Auto Dry Fan ROOM TEMP SPEED Accessory Connecting Cable Fixing Screw (2EA)
  • Page 6 Part Description Simple Wired Remote Controller 1. Operation Display Panel PQRCFCS0 2. On/Off Function Defrost Preheat Out door Room Temp 3. Fan Speed Button Total on Central Run 4. Temperature Control Button Cooling Heating Auto Dry Fan 5. Room Temperature Check...
  • Page 7: Installation Method

    Installation Method Installation Method Put the installation paper on the place and determine the position and height of the fixing screws of the wired remote controller. • Refer to the printed side of the installation paper. The position of the fixing screws Main Plug the connecting cable into the indoor unit.
  • Page 8: I Necessary Functions Before Using

    Instead the product will operate in several modes such as cooling, strong wind, comp-on. If you want to set the trial operation mode, press the Room Temperature button and the fan speed button same time for three seconds. PQRCFCS0 Defrost Preheat Out door...
  • Page 9: Setting The Central Control Address

    You don't need to set address if you don't use central controller. If you want to set the address on the display panle, press both temperature control buttons (▲/▼) same time for three seconds. PQRCFCS0 Press the temperature-increasing button to change the Defrost Preheat Out door group number.
  • Page 10: Esp Function

    Press the room temperature button and temperature incrreasing button L same time for three seconds PQRCFCS0 Set the volume of each fan speed(Low, Medium, Hi) Defrost Preheat Out door by using the temperature control button.
  • Page 11: I How To Use The Mode Selection Button

    On/Off button. The cooling mode can be set from Central Controller only. Press the temperature button and set the desired temperature lower than the current room temperature. (18~30°C) PQRCFCS0 A click of the button will increase the desired temperature by 1°C. Defrost Preheat Out door A click of the button will decrease the desired temperature by 1°C.
  • Page 12: Heating Operation

    On/Off button. The heating mode can be set from Central Controller only. Set the desired room temperature higher than the current room temperature. (16~30°C) PQRCFCS0 A click of the button will increase the desired temperature by 1°C. Defrost Preheat Out door Room Temp A click of the button will decrease the desired temperature by 1°C.
  • Page 13: Auto-Operation

    How to use the Mode Selection Button Auto-Operation Set the operation mode to auto-operation by central controller after pressing the On/Off button. PQRCFCS0 Defrost Preheat Out door When the room temperature is lower than the desired Room Temp temperature: Heating Operation starts...
  • Page 14: Dry(Dehumidification) Operation

    Dry(Dehumidification) Operation Dry(Dehumidification) by lowering temperature slightly If you want to start the dry operation, press On/Off button. The dry operation can be set from Central Controller only. PQRCFCS0 Defrost Preheat Out door Room Temp When the dry operation is selected, “dh” will be shown...
  • Page 15: Fan Speed Selection

    • The initial fan speed is "Hi" • If the product is not compatible with the fan speed control, it will not function as per your selection. Fan Speed Selection in Cooling Operation PQRCFCS0 Defrost Preheat Out door Room Temp...
  • Page 16: Indoor Temperature Display

    How to use the Mode Selection Button Indoor Temperature Display When the room temperature button is pressed on the remote controller, the indoor temperature will be displayed for about 5 seconds, then goes back to the previous screen. PQRCFCS0 Defrost Room Temp ROOM TEMP SPEED...
  • Page 17: Child Lock

    "CL" will be displayed on the display panel and then it will come back to the original mode. Now a click of another button will not be recognized and the "CL" is being shown on the display panel for three PQRCFCS0 Defrost Preheat Out door seconds due to child lock.
  • Page 18 Memo 18 Simple Wired Remote Controller...
  • Page 19 P/No.: 3828A20561E Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.