1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Make sure that there are no kinks in the
flexible gas line.
4. Once the exhaust vent connection is made, remove the corner
posts and cardboard.
L@_v@iil !ii31i"!i;_,@[
Check the levelness of the dryer. Check levelness first
side to side, then front to back.
You can change your door swing from a right-side opening to a
left-side opening, if desired.
B
If the dryer is not level, prop up the dryer using a wood block.
Use a wrench to adjust the legs up or down and check again
for levelness.
1.
2.
Place towel (A) on top of dryer to protect surface.
Open dryer door. Remove bottom screws from cabinet side of
hinges (B). Loosen (do not remove) top screws from cabinet
side of hinges.
3. Lift door until top screws in cabinet are in large part of hinge
slot. Pull door forward off screws. Set door (handle side up) on
top of dryer. Remove top screws from cabinet.
4. Remove screws attaching hinges to door.
5. Remove screws at top, bottom, and side of door (5 screws).
Holding door over towel on dryer, grasp sides of outer door
and gently lift to separate it from inner door. Do not pry apart
with putty knife. Do not pull on door seal or plastic door catch.
6. Be certain to keep cardboard spacer centered between doors.
Reattach outer door panel to inner door panel so handle is on
the side where hinges were just removed.
7. Attach door hinges to dryer door so that the larger hole
is at the bottom of the hinge.
8. Remove the 4 screws that attach 2 plugs (D) on the left side.
Attach plugs to right side using the same 4 screws.
9.
Insert screws into bottom holes on left side of cabinet. Tighten
screws halfway. Position door so large end of door hinge slot
is over screws. Slide door up so screws are in bottom of slots.
Tighten screws. Insert and tighten top screws in hinges.
10. Close door and check that door strike aligns with door catch
(C). If it is needed, slide door catch left or right within slot to
adjust alignment.