Range Cord - LG LDE3015SW Installation Instructions Manual

Electric double oven range
Hide thumbs Also See for LDE3015SW:
Table of Contents

Advertisement

[-_ ELECTRICAL
CONNECTION
REQUIREMENTS
This appliance must be installed and grounded on a branch
circuit by a qualified technician in accordance with the
National Electrical code ANSl/NFPA NO. 70 - latest edition.
All wiring should conform to Local and NEC.This range
requires a single-phase, 3 wire, A.C 120/208Vor 120/240V60Hz
electrical system. Use only a 3-conductor or a 4-conductor
UL-listed range cord with closed-loop terminals, open-end
spade lugs with upturned ends or similar termination. DO
NOT install the power cord without a strain relief.
A range cord rated at 40 amps with 120/240 minimum volt
range is required. If a 50 amp range cord is used, it should
be marked for use with 1¢8"diameter connection openings.
This appliance may be connected by means of conduit or
power cord. If conduit is being used, go to page 7 for 3 wire
conduit connectionsor page 8 for 4 wire conduitconnections.
• New branch-circuit installations (1996 NEC)
for mobile homes, recreational vehicles, and
installations where local codes do not allow
grounding through the neutral wire require a
4-conductor UL listed range cord or 4 wire
conduit connection.
• Power supply cord and plug should not be
modified, if it will not fit the outlet, have a proper
outlet installedby a qualified electrician.
• Using an extension cord to connect the power is
prohibited. The way to connect the power cord
and plug directly is strongly recommended.
• Electrical ground is requiredon this appliance.
• You should make sure that the power cord is
not pinched by the range or heavy objects.
- Failureto do so can result in serious burns or electrical shock.
_,
,,_
Specified
power=supply-cord
kit rating
Diameter (inches) of Range
Range rating, watts
Specified rating
connection Opening
of power-supply-
120/240 volts
120/208 volts cord kit, amperes Power cord
Conduit
3-wire
3-wire
8,750- 16,500 7,801 - 12,500
40 or 50A
13/8"
11/8"
16,501- 22,500 12,501- 18,500
50
13/4"
1%"
3, 4 - Wire electrical wall Receptacle
FIGURE 3
[=4-7CONNECT
RANGE CORD
• You never remove the protection cover
covering
the rear of lower oven.
- Failureto do so can result in serious damage to power cord.
,, The damage causes serious burns and electric shock.
The Rear Access cover must be removed.
Loosen the
three screws with a screwdriver.
The terminal
block
will then be accessible.
-Terminal
block
Access cover
Cord!Conduit
Rear of lower oven
connection
plate
Protection
cover
FIGURE 4
The Cord/Conduit connection plate is used for the
installation of power cord or conduit. For power cord,
install it with the connection plate as INSTALLED. For
conduit, remove the connection plate located below the
rear of the drawer body and use the conduit hole (11/8 " )
instead of power cord hole (13/8").(Refer to Figure 5 and 6.)
11/8"
13/8" _ ........ _ ............. _
.............
(2.8cm)
1118"
I °C-h°
J
(Conduit)
__ _.__._
_
_
13/8"
.................................
_
_'
(3.5 cm)
Remove the Conduit connection
plate
FIGURE 5
C(_/_rd/Conduit
connection
plate
Strain
relief
Conduit
_Ring
Conduit
Body
I
Assemble the
"qv
strain relief hole
Cord
Strain
! _f_
1_
J
relief
Reinstall the Cord/Conduit
connection
plate
FIGURE 6
6