Fitting

5.1

Fitting the bolts

V Place the polystyrene packaging[1] on the floor.
V Lay the storage tank [2] on the polystyrene with care.
V Fit the M10 x 30mm bolts [3] accordingly into the
bottom of the storage tank.
V Adjust the bolts to level the tank.
5.2

Fitting the temperature sensor

V Using the guide wire on the guide plate[ slide the
clamp spring and the temperature sensor together into
the sensor pocket.
Ensure that the sensor area has contact with
the sensor pocket area for its full length.
Sensor positions:
– M1 = Measuring point for flow temperature sensor top
– M2 = Measuring point for return temperature sensor
(GT1) bottom
(
Fig. 2, page 5)
For information on this refer to the
documentation of your heat pump or of the
control unit.
V Lay the sensor lead through the top opening to the
control unit with care.
V Carefully route the sensor cable to the heat pump
8
1
Fig. 4
Fitting the foot screws
1
polystyrene packaging, top
2
storage tank
3
bolts (x3)
Fig. 5
Primary water storage tank
1
bolts (x3)
2
insulation
3
storage tank
4
sensor pocket (for flow temperature sensor)
and air vent
5
cover cap
6
sensor pocket (for return temperature sensor GT1) - M2
8 716 115 670 (02/2009)
Fitting
2
3
ca. 20
6 720 614 912-01.1RS