Electrical Requirements - Kenmore 79031113110 Installation Instructions Manual

Gas cooktop
Table of Contents

Advertisement

Available languages

Available languages

_The
supply
line must be equipped
with
an approved
manual
shutoff
valve. This valve should
be
located
in the same room as the cooktop
and should
be
in a location
that allows
ease of opening
and closing.
DO NOT block
access to the shutoff
valve. The valve is
for turning
on or shutting
off gas to the appliance.
Shutoff
Valve -
Open position
Figure 23 - SHUTOFF VALVE
Once regulator
is in place,
open the shutoff
valve in the
gas supply
line. Wait
a few minutes for gas to move
through
the gas line.
_
Check
for
leaks.
After connecting
the cooktop
to the gas supply, check the system for leaks with a
manometer.
If a manometer
is not available,
turn on the
gas supply
and use a liquid
leak detector
(or soap and
water)
at all joints and connections
to check for leaks.
Flr_]__
DO NOT use a flame
to check for
leaks from gas connections.
Checking
for leaks with a
flame
may result in a fire or explosion.
Tighten a[[ connections if necessary to prevent
gas leakage in the cooktop or supply line.
Disconnect
this
cooktop
and
its individual
manual
shutoff
valve
from the gas supply
piping
system during
any pressure testing
of that system at test
pressures greater
than
1/2 psig (3.5 kPa or 14"water
column).
|
Isolate
the cooktop
from
the gas suppJy
piping
system
by dosing
its individual
manual
shutoff
valve during
any pressure testing
of the gas supply
piping
system
at test pressures equal
to or less than
1/2
psig (3.5 kPa or 14" water
column).
Electrical
Requirements
120 volt, 60 Hertz, properly
grounded
branch
circuit
protected
by a 15 amp circuit
breaker
or time delay
fuse. DO NOT use an extension
cord with this cooktop.
|
Grounding
Instructions
iMPORTANT
Please read carefully.
For personal
safety, this appliance
must be properly
grounded.
The power cord of this appliance
is equipped
with a
3-prong
(grounding)
plug which
mates with a standard
3-prong
grounding
wall receptacle
(see Figure 25) to
minimize
the possibility
of electric
shock hazard
from
the appliance.
The wall receptacle
and circuit
should
be checked
by
a qualified
electrician
to make sure the receptacle
is
properly
grounded.
Where
a standard
2-prong
wail receptacle
is installed,
it is the personal
responsibility
and obligation
of the
consumer
to have it replaced
by a properly
grounded
3-prong
wall receptacle.
Preferred
Method
Grounding
type
wail receptacle
NOT, under
any circumstances,
cut, remove,
or bypass the
grounding
prong.
Power supply cord with
3-prong
grounding
plug.
Figure 24 - POWER SUPPLY CORD
DO NOT, under any circumstances,
cut or remove the
thlrd
(ground)
prong from the power cord.
_
Disconnect
electrical
supply
cord from
wail receptacle
before
servicing
cooktop.
11