The continuous indoor blower operation can be
obtained with the thermostat system switch set
in any position, including
OFF.
The continuous
indoor
blower
operation
is
typically
used to circulate
the indoor air to
equalize a temperature
unbalance due to a sun
load, cooking, or fireplace operation.
To Maintain Your Air Conditioner--
CAUTION:
Be certain the electrical
power to the
outdoor unit and the furnace/air
handler
is disconnected
before
doing
the
following
recommended
maintenance.
1. Regularly:
a. Clean or replace the indoor air filter at the
start of each heating and cooling season,
and when an accumulation of dust and dirt
is visible on the air filter.
b. Remove any leaves and grass clippings
from the coil in the outdoor
unit, being
careful not to damage the aluminum fins.
c. Check for any obstruction,
such as twigs,
sticks, etc.
2.
Before Each Cooling Season:
If the furnace/air handler blower motor and
the outdoor unit fan motor(s) have oil tubes
at the motor bearings, apply 10 drops of
SAE No. 20 motor oil to each oil tube.
CAUTION:
Do not over-oil,
or oil motors
not
factory-equipped
with oil tubes.
The
compressor
is hermetically
"sealed"
and does not require
lubrication.
3.
Before
Calling a Service
Technician,
Be Certain:
a. The unit thermostat
is properly set -- see
"To Operate
Your Air Conditioner
for
Cooling" and "To Operate Your Furnace
for Heating."
b. The
unit disconnect
fuses are in good
condition, and the electrical power to the
unit is turned on.
1. GENERAL INFORMATION
Read the following instructions
completely
be-
fore performing
the installation.
Condensing Unit Section--
Each condensing
unit is shipped with a refrigerant
charge
ad-
equate to operate the outdoor section with an
indoor matching coil or air handler, and 15 feet
of refrigeration line.
NOTE: DO NOT USE ANY PORTION OF THE
CHARGE FOR PURGING OR LEAKTESTING.
Matching coils and air handlers are shipped with
a small pressurized
holding charge to pressur-
ize them to keep out contaminants.
To release
the pressure,
read the indoor section installa-
tion instructions
carefully.
Liquid and Suction Lines--
Refrigerant grade
copper tubing should be used when installing
the system.
Refrigerant
suction
line tubing
should be fully insulated.
Field
Connections
for
Electrical
Power
Supply --
All wiring must comply with current
provisions
of the "National
Electrical
Code"
(ANSI/N FPA 70) and with applicable local codes
having
jurisdiction.
The
minimum
size of
electrical conductors and circuit protection must
be in compliance
with information
listed on the
outdoor unit data label.
2. SAFETY CONSIDERATIONS
Pressures within the System -- Split system
air conditioning
equipment contains liquid and
gaseous
refrigerant
under pressure.
Installa-
tion and servicing of this equipment should be
accomplished
by qualified, trained
personnel
thoroughly familiar with this type of equipment.
Under no circumstances
should the Homeowner
attempt to install and/or service the equipment.
Labels, Tags, Precautions
-- When working
with this equipment, follow all precautions in the
literature, on tags, and on labels provided with
the equipment.
Read and thoroughly
under-
stand the instructions
provided with the equip-
ment prior to performing
the installation
and
operational
checkout of the equipment.
Brazing
Operations
-- Installation
of equip-
ment may require brazing operations.
Safety
codes must be complied with.
Safety equip-
ment (e.g.; safety glasses, work gloves, fire
extinguisher,
etc.) must be used when perform-
ing brazing operations.