Electricalconnection
Electrical Shock Hazard
Electrical ground is required on this
appliance.
Do Not connect to the electrical supply until
the appliance is permanently grounded.
Disconnect the power to the junction box
before making the electrical connection.
This appliance must be connected to a
grounded, metallic, permanent wiring system
or a grounding connector should be
connected to the grounding terminal or wire
lead on the appliance.
Failure to do so could result in death or
serious injury.
brass
terminal nuts
terminal
block
terminal
block cover
Remove the terminal block cover located
• on the back of range.
Depending on your electrical supply,
• make the three-wire or four-wire
connection following the "Power supply cord
method" or "Direct wire method" instructions.
This appliance is manufactured with the neutral
terminal connected to the cabinet. Use a three-
wire, U.L.-listed, 40-ampere power supply cord
(pigtail); or if local codes Do Not permit
grounding through the neutral, use a four-wire
power supply cord rated at 250 volts, 40-amperes
and investigated for use with ranges. (See "Four-
wire electrical connection.")
knockout
knock out
opening for
. opening for
40-ampere
power
power
supply cable
supply cord
1. Disconnectthe power supply.
2. Remove the knockoutfor the 40-ampere
power supply cord.
3. Assemble a U.L.-listed strain relief in the
opening.
4. Insert the power supply cord through the
strain relief, allowing enough slack to easily
attach the wiring to the terminal block.
5. Use only ring-type terminals to connect the
power supply. To secure the power supply
cord, use the 3/8" brass nuts attached to the
terminal blockcover. Be sure nuts are installed
tight.
6. Complete electrical connection according to
your type electrical supply ("Three-wire
electrical connection" or "Four-wire electrical
connection.")
Three-wire electrical connection:
silver-colored
screw
I
grounding
Neutral
link
(center wire)
line 1
U.L-listed strain relief
and 40 ampere range
power supply cord
Figure 3
Use this method ONLY if local codes PERMIT
connecting cabinet-grounding conductor to neutral
wire of power supply cord.
7. Use the brassterminal nuts attached to the
terminal blockcover to connect the neutral wire
(center wire) to the silver-colored terminal screw
on the terminal block. See Figure 3.
8. Connect the other two wires to outer terminal
screws on the terminal block. See Figure 3.
9. Do Not loosen factory-installed nuts already on
the terminal. Tighten nuts with 3/8" nut driver
for proper electrical connection.
10. Tighten the strain relief screws.
11. Reinstallthe terminal block cover.
12. Plug power supply cord into grounded electrical
outlet.
Four-wire electrical connection:
grounding
Figure 4
irounding-link
screw
green
grounding
wire
_o
nd_e_-
S
Figure 5
silver-colored
tbl r cmk n:¢lre_
green .
I
grounding _
neutral wire
ter wire)
ed strain relief
mpere range
power supply cord
Figure 6
Use this method for mobile homes and whenever
four-wire installation is required.
7. Remove the grounding-link screw from the
range frame. Save the grounding-link screw.
Bend up the grounding link so that it does not
contact the range. See Figure 4.
8. Connect the green grounding wire from power
supply cord to the range using the grounding-link
screw. The grounding wire must be attached first
and must not contact any other terminal. See
Figure 5.
9. Connect the neutral (center wire) wire to the
center, silver-colored terminal screw on the
terminal block using the brass nuts that are
attached to the terminal blockcover. See
Figure 6.
10. Connect the other two wires to the outer
terminals on the terminal block.See Figure 6.
11. Do Not loosen the factory installed nuts already
on the terminal. Tighten nuts with 3/8" nut driver
for proper electrical connection.
12. Tighten the strain relief screws.
13. Replace the terminal block cover.
14. Plug power supply cord into grounded electrical
outlet.
This appliance may be connected directly to the fuse
disconnect or circuit breaker box; or with a U.L.-listed,
40-ampere range power supply cord (pigtail). Depending
on your electrical supply, make the required three-wire or
four-wire connection.
1. Disconnect the power supply.
2. Remove the knock-out for the
power supply cable.
3. Assemble a U.L.-listed conduit
connector in the power supply cable
opening.
4. Strip outer covering back 3 inches
from end, exposing the wires.
Strip the insulation back 1 inch
from the end of the each wire.
5. Form the bare wire into a "U"
shaped hook.
6. Insert the power supply cable
through the conduit connector,
allowing enough slack to easily attach the wiring
terminal block.
7. Complete electrical connection according to your type
electrical supply ("Three-wire electrical connection" or
"Four-wire electrical connection.")
U.L.-listed conduit
connoctor,_
Three-wire
electrical connection:
silver-colored
terminal block
screw
grounding
link
(white wire)
line
U.L.-listed
conduit
connector
Figure 7
and power supply cable.
Use this method ONLY if local codes PERMIT
connecting cabinet-grounding conductor to neutral
wire of power supply cable.
8. Use the brass terminal nuts attached to the
terminal blockcover to connect the neutral wire
(white wire) to the silver-colored terminal screw on
the terminal block. See Figure 7.
9. Connect the other two wires to outer terminal
screws on the terminal block. See Figure 7.
10. Do Not loosen factory-installed nuts already on
the terminal. Tighten nuts with 3/8" nut driver for
proper electrical connection.
11. Tighten the locking ring and clamping screws of
the conduit connector.
12. Reinstall the terminal block cover.
Four-wire electrical connection:
Figure 8
grounding-
grounding link
_link
screw
bare wire
from _ J _l_=RiJi_;_
_L1grounding-link screw
power
"
--
I
su.p.p,y
I
silver-colored
CaDle
I
_X_(_//i//_
I
terminal block screw
Figure 9 ___L__-_
neutral.
I-
w.irr:,(wh'te
bare wire from
_._//_,_,...
I
powersuppIy -/
I"_j..k.x_/,,1J _
I
cable
r
Ii__
I
I _
U.L. listed conduit
connector
and
Figure 10
power
supply
cable
Use this method for mobile homes and whenever
four-wire installation is required.
8. Remove the grounding-link screw from the range
frame. Save the grounding-link screw. Bend up the
grounding link so that it does not contact the range.
See Figure 8.
9. Connect the bare grounding wire from power
supply cable to the range using the grounding-link
screw. The grounding wire must be attached first
and must not contact any other terminal. See
Figure 9.
10. Connect the neutral (white wire) wire to the
center, silver-colored terminal screw on the terminal
block using the brass nuts that are attached to the
terminal block cover. See Figure 10.
11. Connect the other two wires to the outer
terminals on the terminal block. See Figure 10.
12. Do NOT loosen the factory installed nuts already
on the terminal. Tighten nuts with 3/8" nut driver for
proper electrical connection.
13. Tighten the locking ring and clamping screws of
the conduit connector.
14. Replace the terminal block cover.