Download Print this page

Technical Specifications - HP DL180 Quickspecs

Hp proliant generation 6 (g6)
Hide thumbs Also See for DL180:

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
(per power supply)
System Inlet
Temperature
DA - 13248 Worldwide — Version 53 — September 24, 2012
HP ProLiant DL180 Generation 6 (G6)
3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
efficient
Click on the system of interest. Example: DL180 G6
Follow the instructions of the next screens.
Rated Steady-State
Power
Maximum Peak Power
Operating
45.0 lb (16.80 kg)
32.0 lb (11.94 kg)
90 -- 132 VAC,
180 - 264 V
460 Watt
7.1 A (at 120 VAC)
3.5 A (at 240 VAC)
750 Watt
7.4 A (at 120 VAC)
3.6 A (at 240 VAC)
50 to 60 Hz
460 & 750 watt - 852 W
460 Watt
1773 BTU/hr (at 120
VAC)
1715 BTU/hr (at 240
VAC)
750 Watts
2892 BTU/hr (at 120
VAC)
2797 BTU/hr (at 240
VAC
www.hp.com/go/proliant-energy-
460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
Page 54