Power Supply Cord
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
Electrical
Shock Hazard
Disconnect
power before servicing.
Use 8 gauge copper
or 6 gauge aluminum
wire.
Electrically
ground
range.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1. Disconnect
power.
4. Add strain relief.
2. Use Phillips screwdriver to remove the terminal block cover
Style 1: Power supply cord strain relief
screw located on the back of the range. Pull cover down and
toward you to remove cover.
Assemble a UL listed strain relief in the opening.
3.
Remove plastic tag holding three 10-32 hex nuts from the
middle 3ost of the terminal block.
A. UL listed strain relief
Feed the power supply cord through the strain relief in the
opening of the cord/conduit
plate. Allow enough slack to
easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
6