8.4 Install the Wired Sensors and Electricity equipments
Please help to see below wiring diagram, then fixed the related wired
sensors, the sensors connect to the related digital inputs.
Tips!
1) Please setup the NC, NO, EOL type in the Menu correctly;
2) If you setup the Nodes type as NC(Default), and the sensor type must be NC. Please
see below diagram.
3) If you setup the input type as EOL, then please contact a 2.2K Resistor in series with
every inputs. Please see the below diagram.
4) If you setup the input type as NO, then please keep the two points of the inputs by
free, and the sensor type must be NO. Please see the below diagram.
5) The Unit built-in 240VAC@3A rated relay. Please make sure the power cord rated
while you connect to equipment device. also, please make sure the power
consumption is less than 250W for long time working. If you need heavy equipment,
please connect an additional relay ;
6) The R1+ and R1- is for alarm-link output, when the system alarm, will close for 4
minutes, the rated output power is 700W. If you need heavily equipment, please
connect an additional relay .
7) The R2+ and R2- is the relay output for SMS Command, CC is close, DD is open, EE
is inquiry the status.
8) The +12VDC is for the Detectors, if the detectors need 12VDC power, then please
contact it to the +12VDC. The 12VDC power is from external power, not from backup
battery. So please note: When AC power failure, the +12VDC point will no power
supply.