  • Page 1 A New User Friendly Concept GSM SMS Alarm For Your Assets! GSM Alarm Control Panel User Manual S110 Ver 1.10 Date Issued: 2010-09-01 All rights reserved by King Pigeon Hi-Tech.Co.,Ltd.
  • Page 2: Table Of Contents

    Quality Warranty -----------------------------------------------------------------------------30 Trouble Shooting Guide-------------------------------------------------------------------31 This handbook has been designed as a guide to the installation and operation of S110. Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products.
  • Page 3: Brief Introduction

    A Top Safety and Protection Solution In The Worldwide! 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It based on Wireless GSM Communication network, integrated Lcd Menu display and Computer technology.
  • Page 4: Standard Packing List

    A Top Safety and Protection Solution In The Worldwide! mainframe. Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer. Waterproofness The product is not waterproof. Please install it at dry places and keep it dry. 3. Standard Packing List Control Unit X1 Wireless Magnetic Door Sensor X1 Wireless Remote Controls X 2...
  • Page 5 A Top Safety and Protection Solution In The Worldwide! Interface 1 Description External Power Connector, Connect to 2A@12V DC power Power through AC/DC Adaptor. Siren Will start for 60seconds when alarm. The siren or strobe siren should be <12V DC. GSM ANT Connect the GSM ANT, if the GSM signal is not strong, then please change the 3dB GSM ANT.
  • Page 6 A Top Safety and Protection Solution In The Worldwide! Ground point, connect to another wire of the wired Detector. Digital input 4, connect to one wire of the wired Detector. Digital input 5, connect to one wire of the wired Detector. Ground point, connect to another wire of the wired Detector.
  • Page 7: Features

    A Top Safety and Protection Solution In The Worldwide! 5. Features 5.1 The advantages of the GSM Alarm System Two-way Voice communication or wiretap are available; LCD displays the entire setup menu; Armed, Partial Armed(At House or Stay), Disarmed, SOS are available; Armed delay, alarm delay, siren work or not, more other functions are Programmable by user;...
  • Page 8 A Top Safety and Protection Solution In The Worldwide! 5.2 Functions & Features of the GSM Alarm System GSM Frequency: Dual-Band(900/1800/1900MHz), Quad-Band is optional(850/900/1800/1900Mhz) ; Supports armed, Partial armed(At House or Stay) or disarmed, SOS by remote control or mainframe keyboard; Supports armed, disarmed, inquiry mainframe status, switch on or off relay output by SMS Commands;...
  • Page 9: Settings

    A Top Safety and Protection Solution In The Worldwide! 17) Standby internal rechargeable battery which can last 18 hours; 18) Based on the GSM communication network and Operation Menu Display technology, apply to wide range situations. 6. Settings Tips! Please insert the SIMCard firstly, and install the GSM Antenna then power on it. Also, you can insert the SIMCard after you setup.
  • Page 10 A Top Safety and Protection Solution In The Worldwide! phone is far from the , at least 500meters. Otherwise, the near-cross will make lots of noise interference. Please setup at least one alarm alert number, otherwise the mainframe will only activate the siren to work 6 times, this is to remind you setup alarm numbers.
  • Page 11 A Top Safety and Protection Solution In The Worldwide! 6.1.2 LCD ICONS Description The unit uses the icons to descript the present status; it will be more user friendly. : Enabled the Timer to arm and disarm function; otherwise, will not display it. : Timer to Arm, has setup a time point to enter armed mode directly.
  • Page 12 A Top Safety and Protection Solution In The Worldwide! ---To check the settings and event records of the 1. View system ---To setup the system functions, requires password, 2. Setup the default password is 1234. 6.2.1 View ---To check the alarm records, up to 100 event 1.
  • Page 13 A Top Safety and Protection Solution In The Worldwide! ---To add or remove wireless sensors or remote 1. Add/Del RF Parts controls and edit their attributes. 2.Wired Zones Set ---To setup Wired Zone parameters of the system. 3.Basic Setting ---To setup basic parameters of the system. 4.
  • Page 14 A Top Safety and Protection Solution In The Worldwide! sensor to this zone. Press Up or down button on the keyboard to check the other Zones. Press Enter to edit it. After you pressed the Enter button, you can select the zone attribute, and then press Enter, you can see “Turn on the device”...
  • Page 15 A Top Safety and Protection Solution In The Worldwide! stay mode, once the sensor in these Smoke Fire Alarm zones triggered will alarm. Watchdog Zone, the attribute can not be modified. In arm or disarm or stay mode, once the sensor in this Watchdog alarm zone triggered in the preset time, will not alarm, if the sensor hasn’t...
  • Page 16 A Top Safety and Protection Solution In The Worldwide! Intrusion from Guarden Fence Normal 24-Hour zones, This attribute can not 24Hours zone alarm be modified. In arm or disarm or stay mode, once the sensor in these zones 24Hours zone alarm triggered will alarm immediately.
  • Page 17 A Top Safety and Protection Solution In The Worldwide! different GSM Operator with different communication protocols. Our system is with the international communications protocols. The Auto-dial Tel. Number can dial to the , 6 tones later, can wiretap the system site. Before 6 tones, if somebody answers the calling, then can create two-way voice communication.
  • Page 18 A Top Safety and Protection Solution In The Worldwide! 30Min.” to the first SMS Alert numbers after the AC power failure 30minutes, if the power is recovery then will send SMS “AC Power is OK.”. Default is disabled. There’s no delay for Stay Mode. 6.2.2.4 Advanced Setting ---To setup the starting time to arm and the Ending 1.Edit Timer...
  • Page 19: Operating Instructions

    A Top Safety and Protection Solution In The Worldwide! For Wireless Zone Name, the format is: Password+#+M+Zone Serial Number+#+New Zone Name+#, the Max. Character for the zone name is 32. The Zone Serial Number is 01~16 corresponding to the LCD Menu and 6.2.2.1 table.
  • Page 20 A Top Safety and Protection Solution In The Worldwide! keyboard then select Arm, the Control Unit enters arm status (delay time according to the setting), the ICON will be on. Under this status, any sensor triggered, the control unit will alarm, if answered the call, the siren will stop and can listen in the alarm area by phone.
  • Page 21 A Top Safety and Protection Solution In The Worldwide! xxxxAA Example “xxxx” stands for the password 1234AA (1-4 digits). Return SMS When the Password is 1234 All Armed Mode activated. 7.2.2 Disarm xxxxBB Example “xxxx” stands for the password 1111BB (1-4 digits).
  • Page 22: Installation

    A Top Safety and Protection Solution In The Worldwide! xxxxEE “xxxx” stands for the password (1-4 digits). Return SMS Armed or At House or Disarmed AC Power is Ok or AC Power is failed GSM Value is 17 or other value Output Relay is Closed or Output Relay is opened Notice:...
  • Page 23 A Top Safety and Protection Solution In The Worldwide! In some circumstances an Infrared beam fence is more appropriate than magnetic sensors. i.e. veranda, picture window balcony, boundary wall e.t.c. Wireless glass break sensor can also be used (see below) For a Scrolling Steel Door, a special Wireless Scroll Steel Door magnetic sensor must be used due to interference of the wireless signal caused by the steel door.
  • Page 24 A Top Safety and Protection Solution In The Worldwide! Scroll Steel Door 8.3 Install the wireless PIR Motion Sensor The PIR sensor will detect a person since human temperature is different to ambient temperature. When triggered, the PIR will signal the Control Unit. Apply the detection area illustration below when installing.
  • Page 25 A Top Safety and Protection Solution In The Worldwide! 8.4 Install the Wired Sensors and Electricity equipments Please help to see below wiring diagram, then fixed the related wired sensors, the sensors connect to the related digital inputs. Tips! 1) Please setup the NC, NO, EOL type in the Menu correctly; 2) If you setup the Nodes type as NC(Default), and the sensor type must be NC.
  • Page 26 A Top Safety and Protection Solution In The Worldwide! Page of 32 Ver 1.10...
  • Page 27 A Top Safety and Protection Solution In The Worldwide! 8.5 Install the Control Unit In order to avoid destruction of the Control Unit by intruders, please install it in a concealed location, convenient to the operator. If applicable, ensure that an uninterruptible AC power outlet is available near the Control Unit.
  • Page 28 A Top Safety and Protection Solution In The Worldwide! 9. Add Wireless Sensors to the Control Unit Notice: 1. Some wireless sensors must be coded by manual as below 9.1 step; some wireless sensors needn’t coded by manual, because of we will use the learning code sensor. The learning code wireless sensor you can omit the 9.1 step, can be learned to the system directly, like the PIR-100B and DM-100A.
  • Page 29: Add Wireless Sensors

    A Top Safety and Protection Solution In The Worldwide! 9.2 Enter the RF Sensor Adding Menu.(See 6.2.2.1 Add/Del RF Parts) Select the Zone number, press Ok, finished it then press OK to select the Normal Type Or Stay Type, then following the instruction: 1.Turn On the Device, means trigger the RF sensor, the system will show a code, then press Enter Key on the Keyboard.
  • Page 30: Important Information

    A Top Safety and Protection Solution In The Worldwide! Rated Voltage: 9~12VDC 2A Standby current: 30-40mA Siren Output Voltage: 12VDC Working temperature: -10 +60 ; Storage temperature:-20 Relative humidity: 10-90%, No condensation Work frequency: 900/1800/1900MHz or 850/900/1800/1900MHz Communication protocol: GSM PHASE 2/2+ (include data service) Wireless sensor receiving frequency: 433.92 MHz Wireless sensor permission quantity:...
  • Page 31: Maintenance

    A Top Safety and Protection Solution In The Worldwide! 12. Maintenance 1) If the Control Unit works, while the remote control and other sensors fail, please check and change the battery. 2) If the remote control works, but the Control Unit fails to send SMS texts, switch the power of Control Unit off and switch it on after one minute .
  • Page 32 A Top Safety and Protection Solution In The Worldwide! transmission 2) Wireless sensor used 2) Please correct the resistor value to 3.3M short PT2262 IC, and Ohm of the PT2262 Wireless sensor; incorrect Value; 3) Please pull out the wireless sensor 3) Haven’t pull out antenna;...