Integration
Time MS
Write Frame
Rate Time LS
Write Frame
Rate Time 2
Write Frame
Rate Time MS

3.3 Reading the Camera Type

This read command returns an 8-bit value unique to the type of camera interrogated. A
6M3P will return a value of 33h when this command is issued. This is useful for
applications that need to function with multiple DALSTAR camera types.
Example: Read the camera type
Binary
Hex

3.4 Reading the Firmware Revision

This command returns a byte in which the lower nibble is the revision number for the
clock board firmware and the upper nibble is undefined. The ability to read this value
may assist in customer support issues.
Example: Read the firmware version
Binary
Hex

3.5 Resetting the Camera

This is the only other "write" command that is not followed by a data byte. This
command resets all clock board registers to their default values (the values used at
power-up).
Table 11: Default values in effect after reset
Feature
Frame Rate (fps)
Integration Time (ms)
Resolution (pixels)
Video Gain
DALSA
8Dh
NA
8Eh
NA
nd
8Fh
NA
Command
Value Returned
(6M3P)
1100 0011
0011 0011
C3h
33h
Command
1100 0101
C5h
6M3P Default
1
638
3072x2048
1x
integration time
7:0
LS byte of 24 bit frame
rate time
nd
7:0
2
byte of 24 bit frame
rate time
7:0
MS byte of 24 bit frame
rate time
23
6Bh
04h
01h
03-32-10005-02