Summary of Contents for GARDINER TECHNOLOGY 2897PDF

  • Page 1: User Guide

    Gardtec 350+ GARDINER TECHNOLOGY 2897PDF Gardtec 350+ Quick Start User Guide...
  • Page 2: Caring For Your System

    Introduction This Quick Start Guide is intended to help end users who are new to security systems in the day to day use of the system. We recommend that this guide is used in conjunction with the end user manual that was supplied with the control panel. Your Gardtec 350 Control Panel will have been fully programmed by your installation engineer to suit your needs.
  • Page 3 Tampers & PAs Your security system protects itself against tampering. In the event of any control equipment, detectors or sounders being opened or cables being cut the internal and/or the external will sound. Dependant on the level of system you have installed this may require an engineer call-out to reset the system.
  • Page 4: Power Led

    Power LED The Power LED gives an indication of that the mains supply to the unit is good. It should be illuminated at all times except when User Programming mode is being used. Please refer to User Programming Mode section for more details. Setting the System When you set the system fully all zones are active after the setting delay has expired.
  • Page 5: Unsetting The System

    To Part Set the System For Part Set 1 For Part Set 2 For Part Set 3 Then retire to an unprotected area Note: Your engineer may have programmed the Part Set exit sounders as silent. If so a single beep will be given when the exit time expires. Unsetting the System Your installation engineer will have defined to you what route you should take when entering the premises with the system set.
  • Page 6: Resetting After An Alarm

    Resetting After An Alarm After an alarm all the LEDs will be flashing. Pressing No will display the cause of the alarm for 3 seconds. For example. System is Unset. Z 3 illuminated. All LEDs are flashing. Zone 3 was activated when system was set.
  • Page 7: User Programming Mode

    User Programming Mode To enhance the flexibility of the Gardtec 350 control panel there are five user programmable options available. When programming the user options the display is via the five zone LEDs and the legend to the right of the LEDs is used (see illustration below).
  • Page 8 TEST This option allows a Master User to test the system zones and sounders. This option allows a Master User to view the system Event Log. CHIME One or more system zones may have been programmed as chime zones by your installation engineer.
  • Page 9: Testing The System

    The display will show. If you wish to Remove more zones return to To set the system with the Zone(s) you selected Removed Exit Wait After exiting and securing the premises always wait until the exit sounders have stopped before leaving. Note: The selected zones have been Removed for this one set only.
  • Page 10 The display will show. The display will show. The display will show. This is Test Mode. You may now ‘walk Test’ the system. Each time you activate a zone the internal sounder will sound and the corresponding LED will illuminate on the control panel.
  • Page 11: Viewing The Log

    Viewing The Log With the system in Day Mode (Unset). The display will show. The display will show. The display will show.
  • Page 12 The display will now show the last system event and will vary dependant on what that event was. Whilst using the Log Mode the No key is used to move to the previous event and the Yes key is used to move to the next event. Whilst Viewing The Log Moves to previous event Moves to next event...
  • Page 13: Turning Chime On/Off

    Turning Chime On/Off Chime zones will have been previously programmed by your installation engineer. A Master level user may turn the Chime function On or Off. Zones that are programmed as Chime zones will give a low level ‘beep’ sequence when activated. With the system in Day Mode (Unset).
  • Page 14: Programming User Codes

    The display will show. The display will show. To change from On to Off or Off to On To Escape back to Day Mode. Programming User Codes Up to nine user codes may be programmed into the 350+ control panel, each user code has a predetermined level of access.
  • Page 15 The sequence for programming User Codes is. Enter User Code Programming Mode Enter the User Number (1 to 9) you wish to program Enter the Code you require for the User Re-Enter the Code you require for the User Return to Day Mode This is shown step by step below.
  • Page 16 The display will show. The display will show. The display will show.
  • Page 17 The display will show. The display will show. Enter User Number (1 to 9) Note: Tamper LED has rapid flash The display will show. Enter New Code Note: Tamper LED has slow flash...
  • Page 18 The display will show. Enter New Code Again Note: Tamper LED has faster flash The display will show. To Escape back to Day Mode Note: To delete a User Code enter 0000 as the Code. User Number 1 the main system code, therefore it may only be changed and not deleted. Additional information is contained within the User Manual that was supplied with the Gardtec 350 Control Panel.