C.
Level and Position Range - Level range by adjusting
the (4) leveling legs with a wrench. Note: A minimum
clearance of 1/8" is required between the bottom of the
range and the leveling leg to allow room for the bracket.
Use a spirit level to check you r adjustments.
Slide range
back into position. Visually check that rear leveling leg is
inserted into and fully secured by the Anti-Tip Bracket by
removing lower panel or storage drawer. For models with
a warmer drawer or broiler compartment, grasp the top
rear edge of the range and carefully attempt to tilt it
forward.
(17ram)
%
%
Range Side
%
2.
Provide
an
adequate
gas supply.
This unit is pre-set to operate on 4" natural gas manifold
pressure. A convertible
pressure regulator is connected to
the manifold and MUST be connected in series with the gas
supply line. If the LP/Propane conversion kit has been used,
follow instructions
provided with the kit for converting the
pressure regulator to LP/Propane use.
Care must be taken du ring installation of range not to obstruct
the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water column
pressure. The inlet pressure to the regulator must be at least
1 inch greater than regulator manifold pressu re. Examples: If
regulator is set for natural gas 4 inch manifold pressure, inlet
pressure must be at least 5 inches; if regulator has been
converted for LP/Propane
gas 10 inch manifold pressure,
inlet pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted according to
the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
I
• -_ 11-1/2"
II
Area for
120V Outlet on Rear of
Wall and Area for Thru
the Wall Connection of
Pipe Stub and Shut Off
Valve is Shaded Area.
the FloorConnection of
Pipe Stub and Shut Off Valve.
Wall
Edge
3.
Seal
the openings.
Seal any openings in the walt behind the range and in the floor
under the range after gas supply line is installed.
4.
Connect
the range
to the gas supply.
To prevent leaks, put a pipe joint sealant on all male (outside)