Download Print this page

Frigidaire CPMC3085KF3 Installation Instructions Manual page 2

27" (68.6cm), 30" (76.2cm) microwave/wall oven combination

Advertisement

Available languages

Available languages

important
Notes
to the
Installer
1.
Read all instructions contained in these installation
instructions before installing the combination oven.
2.
Remove all packing material from the oven
compartments before connecting the electrical supply
to the wall oven.
3.
Observe all governing codes and ordinances.
4.
Be sure to leave these instructions with the consumer.
5.
Oven door may be removed to facilitate installation.
6.
THiS COMBINATION OVEN IS NOT APPROVED FOR
STACKABLE OR SIDE-BY=SIDEINSTALLATION.
important
Note
to the
Consumer
Keep these instructions with your Owner's Guide for
future reference. Do not discard oven removal tools found
in the literature bag.
IMPORTANT SAFETY
INSTRUCTIONS
• Be sure your combination
oven is installed
and
grounded
properly
by a qualified
installer
or
service technician.
• This wall oven must be electrically
grounded
in
accordance
with
local codes or, in their absence,
with the National
Electrical Code ANSI/NFPA
No.70- latest edition
in United Sates, or with CSA
Standard
C22.1, Canadian
Electrical
Code, Part 1,
in Canada.
Stepping, leaning
or sitting
on the
door of this wall oven can result in serious injuries
and can also cause damage
to the wall oven.
• Never use your wall oven for warming
or heating
the room. Prolonged use of the wall oven without
adequate ventilation can be dangerous.
The electrical
power to the oven must
be shut off while
line connections are being made.
Failure to do so could result in serious injury or
death.
1. Carpentry
Refer to page 1 for the dimensions applicable to your
appliance, and the space necessary to receive the
combination
oven. The oven support surface may be
solid plywood or similar material, however the surface
must be leveled from side to side and from front to rear.
2. Electrical
Requirements
This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker
or fuse. To know the circuit breaker or fuse required
by your model, see the serial plate to find the wattage
consumption and refer to table A to get the circuit
breaker or fuse amperage.
ApplianCe
Protedi0n,
ApPliance
Protection
Rating Watts
Circuit
Rating Watts.
Circuit
240V
Recommended
208V
Recommended
Less than 4800W
20A
Less than 4100W
20A
4800W- 7200W
30A
4100W- 6200W
30A
7200W- g600W
40A
6200W- 8300W
40A
9600W and +
B0A
8300W and +
B0A
Table A
Observe all governing
codes and local ordinances
1.A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (red
and black wires). A time-delay fuse or circuit breaker is
recommended. DO NOT fuse neutral (white wire).
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local codes
and ordinances.
An extension
cord should
not be used
with this appliance.
Such use may result in a fire,
electrical
shock, or other
personal
injury. If you need
a longer power cord you can purchase a 10' (3 m) power
cord kit #903056-9010
by calling the Service Center.
2.
These appliances should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from the appliance should
be connected directly to the junction box. The
junction box should be located as shown in Figure 1
and with as much slack as possible remaining in the
cable between the box and the appliance, so it can
be moved if servicing is ever necessary.
3.
A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
2

Advertisement

loading

This manual is also suitable for:

Cpmc3085kf1