Download Print this page

Alcove Or Closet Installation - GE DNCD450GG9WC Installation Instructions Manual

Advertisement

Installation
Instructions
UL-LISTEDFLEXIBLE METAL(SEMI-RIGID) TRANSITIONDUCT
• If rigid metal duct cannot be used, then UL-listed flexible
metal (semi-rigid) ducting can be used (Kit WX08X10077).
• Never install flexible metal duct in walls, ceilings, floors or
other enclosed spaces.
• Total length offlexible metal duct should not exceed8 feet (2.4m).
• For many applications, installing elbows at both the dryer
and the wall is highly recommended (see illustrations
below). Elbows allow the dryer to sit close to the wall
without
kinking and or crushing the transition
duct,
maximizing drying performance.
• Avoid resting the duct on sharp objects.
UL-LISTEDFLEXIBLE METAL(FOIL-TYPE) T RANSITIONDUCT
• In special installations, it may be necessary to connect the
dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY
in installations where rigid metal or flexible metal (semi-rigid)
ducting cannot be used AND where a 4" diameter can be
maintained throughout the entire length of the transition duct.
• In Canada and the United States, only the flexible metal
(foil-type) ducts that comply with the "Outline for Clothes
Dryer Transition Duct Subject 2158A" shall be used.
• Never install flexible metal duct in walls, ceilings, floors or
other enclosed spaces.
• Total length offlexible metal duct should not exceed8 feet (2.4m).
• Avoid resting the duct on sharp objects.
For best drying performance:
1. Slide one end of the duct over the clothes dryer outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position, extend the duct
to its full length. Allow 2" of duct to overlap the exhaust pipe.
Cut off and remove excess duct. Keep the duct as straight
as possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the other clamp.
ELBOW HIGHLY
DO
EXCESSIVE
_EXNHATUHS__
[]
LEVELING DRYER
LEVEL
FRON_TO-BACK.
LEVEL
SIDE-TO-SIDE,
4 LEVELING LEGS
STAND THEDRYER U PRIGHT NEAR THE
FINAL LOCATION ANDADJUST T HE4 LEVELING
LEGS TOMATCH THEHEIGHT O FYOUR WASHER,
ADJUST T HE2ANTI-TIP LEGS TO CONTACT
THEFLOOR,
2 ANTI-TIPLEGS
[] ALCOVE OR CLOSET INSTALLATION
• If your dryer is approved
for installation
in an alcove or
closet, it will be stated on a label on the dryer back.
• The dryer
MUST be vented
to the outdoors.
See the
EXHAUST INFORMATION step 6.
• Minimum
clearance
between
dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. front
3 in. rear
• Minimum
vertical
space from floor to overhead
cabinets,
ceiling, etc. is 52 in.
• Closet doors
must
be Iouvered
or otherwise
ventilated
and must contain
a minimum
of 60 sq. in. of open area
equally
distributed.
If the closet contains
both a washer
and a dryer, doors must contain a minimum
of 120 sq. in.
of open area equally distributed.
• The closet should
be vented to the outdoors
to prevent
gas pocketing
in case of a gas leak in the supply line.
• No other fuel-burning
appliance
shall be installed
in the
same closet with the dryer.
[]
BATHROOM OR BEDROOM INSTALLATION
• The dryer MUSTbe vented to the outdoors. See EXHAUST
INFORMATION step 6.
• The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRICAL
CODE,ANSI/NFPA NO. 70.

Advertisement

loading

This manual is also suitable for:

Dncd450ggbwcDmcd330gj2wc