Installation instructions
USING FLEXIBLE METAL DUCTS
If rigid all-metal duct cannot be used, then flexible all-metal
venting can be used, but it will reduce the maximum
recommended
duct length. In special installations
when it is
impossible to make connection
with the above recommendations,
then UL-listed clothes dryer transition
duct may be used as
transition venting between the dryer and wall connection
only. The
use of this ducting will affect dry time.
If flexible transition
duct is necessary,
the following directions
Ernst
be followed.
• Use the Shortest Length Possible.
• Stretch the Duct to Its Maxinmm
Length.
• Do Not (;rush or Collapse.
° Never Use Transition Duct Inside the Wall or
Inside the DryeI:
° Avoid Resting the Duct on Sharp Objects.
° Venting Must Conform
to Local Building Codes.
ELBOW HIGHLY
RECOMMENDED
ELBOWSHIGHLY
RECOMENDED
-_
)(
DONOT USE
EXCESSIVE
,
DONOT
_.
CRUSH
FLEXIBLE
_I
EXHAUST
_
AGAINST
--WAL,%
[] ALCOVE OR CLOSET INSTALLATION
• If your dryer is approved
for installation in an alcove or
closet, it will be stated on a label on the dryer back.
° The dryer MUST be vented to the outdoors. See the
EXHAUST
INFORMATION
section.
° Minimum
clearance between dryer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. front and rear
° Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is ,52 in.
° Closet doors must be louvered or otherwise ventilated
and
must contain a minimum
of 60 sq. in. of open area equally
distributed. If the closet contains both a washer and a
dryer, doors must contain a minimum
of 120 sq. in. of open
area equally distributed.
° The closet should be vented to the outdoors to prevent gas
pocketing
in case of a gas leak in the supply line.
• No other fuel-burning
appliance
shall be installed in the
same closet with the dryer.
[]
BATHROOM
OR BEDROOM
INSTALLATION
6
° The dryer MUST be vented to the outdoors. See
EXHAUST
INFORMATION
section 6.
° The installation
must conform with local codes or, in the
absence of local codes, with the NATIONAL
FUEL GAS
CODE, ANSI Z223.
[]
MOBILE OR MANUFACTURED
HOME INSTALLATION
° Installation
must conform to the MANUFACTURED
HOME
CONSTRUCTION
& SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable,
with AMERICAN
NATIONAL
STANDARD
FOR MOBILE
HOME,
NO. 501B.
• The dryer MUST be vented to the outdoors with the
termination
securely fastened to the mobile home
structure. (See EXHAUST
INFORMATION
section 6.)
• The vent MUST NOT be terminated
beneath a mobile or
manufactured
home.
° The vent duct material MUST BE METAL.
° KIT 14-D3A6-33 MUST be used to attach the dryer
securely to the structure.
• The vent MUST NOT be connected
to any other duct,
vent, or chinmey.
• Do not use sheet metal screws or other refastening
devices which extend into the interior of the exhaust vent.
° Provide an opening with a flee area of at least 25 sq. in.
for introduction
of outside air into the dryer room.