Download Print this page
GE CGS990SET2SS Supplementary Manual

GE CGS990SET2SS Supplementary Manual

Lp conversion instructions

Advertisement

Quick Links

LP CONVERSION INSTRUCTIONS
WARNING
This conversion
must be performed
by a qualified installer
or gas supplier in accordance
with the manufacturer's
instructions
and all codes and requirements
of the
authority
having jurisdiction.
Failure to follow ALL
instructions
could result in serious injury or property
damage. The qualified agency performing
this work
assumes responsibility
for the conversion.
The pressure regulator and the burner orifices are set for natural
gas. To use Liquid Propane Gas, the regulator and burner orifices
must be converted.
The LP orifices for the cooktop burners are shipped in a box on the
back of the range.
WARNING
Do not operate the cooktop or oven burners of this range
when using LP (bottled) gas before converting the pressure
regulator and burner orifices from LP gas use. Failure to do so
could cause high flames and toxic fumes which can result in
serious injury.
To adjust your range for use with LP gas, follow these instructions:
1. Disconnect all electrical power, at the main circuit breaker or
fuse box.
2. Shut off the gas supply to the range by closing the manual shut-
off valve.
A.The pressure regulator is located on the rear of the range.
(Some models will have a metal shield protecting the regulator
that must be removed for conversion and reinstalled when
conversion is complete.) The pressure regulator is located in the
lower, right hand side of the range as viewed from the rear.
...............................
Rear of Range
_,,
Regulator
Location
Orifice Box
Location
NOTICE:
If you are using LP (bottled) gas, all adjustments described
in the following steps must be made before you make any
burner adjustments.
B. Unscrew the plastic-protected hex-nut cap.
C. Completely remove the protective plastic cap off the threaded
metal cap.
D. Turn the metal cap so the type of gas being converted to is
displayed and replace the protective plastic cover.
E. Screw the hex-nut cap back into the regulator.
(Do not over tighten}
Rotate cap counter-
clockwise to
Cap assembly
Lever shown closed (Oven Shut Off only)
PUSH LEVER TOWARD REGULATOR TO OPEN
A. Remove the top grates, burner caps and burner heads.
Burner cap
Orifice spud
located through
this opening
_
Burner head
Base
Burner construction
Orifice spuds located
through these
openings.
B.
Front right burner fan some models)
Using a 7 mm or 9/32" nut driver, remove the top burner
orifices. These may be accessed through the burner opening in
the base.
NOTICE:
Save these orifices for future conversion back to natural gas.
C.
Remove the LP orifice spuds, from the box provided. The LP
orifice spuds have the letter "L" on the top.
To aid in identifying the proper location for the LP orifices
during a conversion from Natural Gas to LPGas, paint color
codes have been added to the side or top of the orifice. See
the chart below. Each orifice may also show a series of
engraved marks (I, II, III ...)located
on the top.
_
enotes
0.95mm
Orifice
size opening
Denotes
LP (Propane)
Gas
BURNER
RF
RF1
RF2
RF3
RFC
LF
RR
LR
C
BURNER OUTPUT RATINGS: BTU!HR
BTU
ORIFICE SIZE
COLOR
MARKING
RATE
(mm)
!5,000
!!,000
5,000
9,100
8,000
LOWER
13,500
BAKE
UPPER
!0,000
BAKE
BROIL
!0,000
0.025" (0.63)
0.025" (0.63)
0.025" (0.63)
0.014" (o.s5)
0.039" (0.99)
0.026" (0.66)
O.OS5"(0.89)
O.O34"(O.86)
0.043" (1.09)
0.037" (0.93)
0.037" (0.93)
Black
63L
Black
63L
Black
63L
White
35L
Green/Red
99L
Red/Yellow
66L
Blue/Brown
89L
Orange/
86L
Green
Green
Red
Red
D. Install the LP orifices in their precise locations.
To prevent leakage, make sure the orifice spuds are securely
screwed into the gas supply tubes.
E. For the extra large burner (left front-on some models), the
choke and set screw will be needed. Insert the choke into the
burner head, then inset the set screw into the burner head
and tighten securely. Make sure the screw head is against
the shoulder (within the choke notch) so it does not have any
rotational movement.
G.
For the extra large burner (left front-on some models), the
choke and set screw will be needed. Insert the choke into the
burner head, then inset the set screw into the burner head
and tighten securely. Make sure the screw head is against
the shoulder (within the choke notch) so it does not have any
rotational movement.
Install the old orifice spuds into the metal box along with
these instructions, and replace onto the back of the range for
possible future conversion.
_rew
_
Choke
Orifice spud
@
located
through th
Burner Head
opening
Extended Spud
Base
(on some models)
WARNING
The following adjustments must be made before turning on the gas
to the burner. Failureto do so could result in serious injury due to
high flames and toxic fumes.
BAKE BURNER ORIFICE ON DOUBLE OVEN
1. Remove oven door, oven bottom, and burner. On some models,
a metal shield must be removed. Some models will have a cover
over the burner that will need to be removed.
2.To convert to LP,replace orifice hood with LP hood supplied in kit
with range.
NOTICE:
Save these orifices for future conversion back to natural gas.
Bake
"_%
/,-/" _dfioCle
i
NOTICE:
This product cannot be converted to LP by adjusting the orifice
hood. The hood must be replaced for LP.
LP CONVERSION INSTRUCTIONS
31-10778
05-11
MP-26

Advertisement

loading

Summary of Contents for GE CGS990SET2SS

  • Page 1 LP CONVERSION INSTRUCTIONS B. Unscrew the plastic-protected hex-nut cap. Remove the LP orifice spuds, from the box provided. The LP For the extra large burner (left front-on some models), the choke and set screw will be needed. Insert the choke into the C.
  • Page 2 BROIL BURNER O RIFICE ( on some models) 10.When all adjustments are made and the results are E.Additionally, for each burner being adjusted, quickly open satisfactory: and close the oven door followed by the storage drawer while To convert to LP,remove burner and replace orifice hood with LP observing flame.

This manual is also suitable for: