Installation instruction
8. Chink the wall and window with soft
sponges or rubber bits in order to
refrain from outside noises coming
in or cooling air going out.
9. Air conditioner being fixed,insert the
power plug in the socket, open the
operation panel cover, turn the temperaure
setting to "Test run", turn successively the
mode selection to "Hi fan" and "Hi cool",
"Lo cool" and "Lo fan", inspect the air
conditioner's start and running performance.
10. If "Test run" is normal, turn mode
selection to ''OFF", turn the temperature
setting to "9". Now the air conditioner is
ready for use.
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similar qualified person.Power cable:3x1.5mm
3. After installation, the power plug should be easily reached.
4. The wiring method should be in line with the local wiring standard.
Maximum:
Indoor side
Minimum:
Maximum:
Outdoor side
Minimum:
D.B/W.B
D.B/W.B
D.B/W.B
D.B
2
12
Drain hose
Fig. 5
32°C/23°C
18°C/14°C
43°C/26°C
18°C
Wall