Troy-Bilt 1925 Owner's Manual page 12

Portable generator
Hide thumbs Also See for 1925:
Table of Contents

Advertisement

Available languages

Available languages

Section 4: Operation
Figure 11 — Generator Adapter Cord Set
The maximum load on each outlet is 20 Amps.The
maximum total load on both yellow wire outlets or both
black wire outlets is 30 Amps.
NOTE: Follow all safety precautions when connecting any
extension cord or device to the generator.
RECEPTACLES
CAUTION
Receptacles may be marked with rating value greater
than generator output capacity.
• NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
• DO NOT overload the generator. See "Don't Overload
Generator".
12 Volt DC, 10 Amp Receptacle
This receptacle allows you to recharge a 12 Volt
automotive or utility style storage battery with the battery
charge cables provided (Figure 12).
Figure 12 — 12 Volt DC, 10 Amp Receptacle
This receptacle can not recharge 6 Volt batteries and can
not be used to crank an engine having a discharged battery.
See the section "Charging a Battery" (page 10) before
attempting to recharge a battery.
120 Volt AC, 20 Amp, Duplex
Receptacles
Each duplex receptacle (Figure 13) is protected against
overload by a push–to–reset circuit breaker.
Figure 13 — 120 Volt, 20 Amp Duplex Receptacle
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA L14–30 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater) (Figure 14).You can use the same 4–wire cord if
you plan to run a 120 Volt load.
Figure 14 — 120/240 Volt AC, 30 Amp Receptacle
4-Wire Cord Set
Y (Hot)
NEMA L14-30
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 7,200 watts of power (7.2 kW)
at 30 Amps for 120 Volts or 240 Volts.The outlet is
protected by a rocker switch circuit breaker.
12
240V
120V
120V
W (Neutral)
X (Hot)
Ground (Green)

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents