Troy-Bilt 1919 Owner's Manual
Troy-Bilt 1919 Owner's Manual

Troy-Bilt 1919 Owner's Manual

Briggs & stratton
Hide thumbs Also See for 1919:
Table of Contents

Advertisement

Available languages

Available languages

O
m
m
/
Y
Owner's Manual / Manual del Propietario
Portable
Generator
/ Generador
Port_til
Model / Modelo 0 19 19
IMPORTANT:
READ
SAFETY
RULES AND
INSTRUCTIONS
CAREFULLY
IMPORTANTE:
LEYO
LA SEGURIDAD
LAS ORDENESY
LAS INSTRUCCIONES
DETENIDAMENTE
Questions? Preguntas?
Helpline
- 1-888-611-6708
M-F 8-5 CT
Troy-Bilt® is a registered trademark ofTroy-Bilt, LLC and is used under licenseto Briggs & Stratton Power Products.
Troy-Bilt® es una marca registrada de Troy*Bilt, LLC y se usaabajo licenciaa Briggs& Stratton Power Products.
BRIGGS
& STRATTON
POWER
PRODUCTS
GROUP,
LLC
I!!H!!!!!I ,,FF,RSON,W,
SCONS,N,U.S.A
0
4
Printed in USA
Manual No. 192258GS Revision 6 (01/27/2004)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Troy-Bilt 1919

  • Page 1 Helpline - 1-888-611-6708 M-F 8-5 CT Troy-Bilt® is a registered trademark ofTroy-Bilt, LLC and is used under licenseto Briggs & Stratton Power Products. Troy-Bilt® es una marca registrada de Troy*Bilt, LLC y se usaabajo licenciaa Briggs& Stratton Power Products. BRIGGS &...
  • Page 2: Table Of Contents

    Safety Rules TABLE OF CONTENTS SAFETY RULES Safety Rules........Know Your Generator ......This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Assembly ........Obey all safety messages that follow this Operation ........8- I I Maintenance........
  • Page 3: Safety Rules

    Section 1: Safety Rules DANGER , WARNING Operate generator ONLY outdoors. WHEN ADDING FUEL Keep at least 2 feet of clearance on all sides of generator for Turn generator OFF and let it cool at least 2 minutes before adequate ventilation. removing gas cap.
  • Page 4 Section 1: Safety Rules CAUTION WARNING See"Don't Overload Generator" on page I I. Start generator and let engine stabilize before connecting electrical loads. ;ENERATOR Connect electrical loads in OFF position, then turn ON for Disconnect the spark plug wire from the spark plug and place operation.
  • Page 5: Know Your Generator

    Features and Controls KNOWYOUR GENERATOR Read this owner's manual and safety rules before operating your generator. Compare this illustrationwith your generator to familiarize yourself with the locationsof various controls and adjustments. Savethis manualfor future reference. Data Tag FuelTank SparkArrester Muffler Choke Lever Circuit Breakers (AC)
  • Page 6: Assembly

    ASSEMBLY Install Wheel The wheel kit is designed to greatly improve the portability Your generator requires some assembly and is ready for of your generator. use after it has been properly serviced with the NOTE: Wheel kit is not intendedfor over-the-road use. recommended oil and fuel.
  • Page 7: Assembly

    Section 3: Assembly BEFORE STARTING Place one end of needlenose pliers on bottom of axle and other end of pliers on top of e-ring. Seate-ring by ENGINE pressing pliers closed. Repeat step 3 through 5 to secure second wheel. To aid support leg assembly,rest generator on cradle, Add Engine Oil and Fuel engine end down.Attach support leg with two •...
  • Page 8: Operation

    Operation USING THE GENERATOR OPERATING G EN ERATO R System Ground CAUTION The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see "Equipment Description", earlier in this manual).
  • Page 9 Section 4: Operation • DO NOT connect 240Vott loads to the 120Volt duplex receptacles. • DO NOT connect 3-phase loads to the generator. • DO NOT connect 50 Hz loads to the generator. • DO NOT OVERLOAD GENERATOR. See"Don't Overload Generator" on page I I. Stopping the Engine Unplug all electrical loads from generator panel...
  • Page 10 Section 4: Operation G EN ERATO R ADAPTER COLD WEATH CORD OPERATION The generator is equipped with a 25' generator adapter cord Under certain weather conditions (temperatures below set designedfor a 240Volt, 30 Amp grounded neutral circuit 40°F [4°C] and a high dew point), your generator may (Figure 5).The generator adapter cord set provides a experience icing of the carburetor and/or the crankcase convenient supply of emergency power into your dwelling so...
  • Page 11 Section 4: Operation DON'T OVERLOAD Plug in and turn on the next load. Again, permit the generator to stabilize. G EN ERATO R Repeat steps 4 and 5 for each additional load. NEVER add more loads than the generator capacity.Take special care to consider surge loads in generator capacity, Capacity as described above.
  • Page 12: Maintenance

    Maintenance GENERAL MAINTENANCE • Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on RECOMMENDATIONS generator.These openings must be kept dean and unobstructed. The Owner/Operator is responsible for making sure that CAUTION alt periodic maintenance tasks are completed on a timely basis;that all discrepancies are corrected;...
  • Page 13: Storage

    STO RAG E Engine Storage manual for engine owner's instructions. The generator should be started at least once every seven claysand allowed to run at least 30 minutes. If this cannot Other Storage Tips be done and you must store the unit for more than •...
  • Page 14: Troubleshooting

    Troubleshooting TROUBLESHOOTING Problem Cause Solution Reset circuit breaker. Circuit breaker is open. Poor connection or defective cord set. Check and repair. NoAC output is available, Connect another devicethat is in Connected device is bad. but engine is running. good condition. Contact Authorized Service Facility.
  • Page 15: Notes

    Notes NOTES...
  • Page 16 Wiring Diagram and Schematic SCHEMATIC BRIDGE RECTIFIER BLUE EXCITATION FIELD BLUE _E£ BLACK GRAY BLUE BLAOK GRAY 22> <33> (44) "OA GRAY 120V/20A (44A) BLUE "2 BLUE (IIA) BLUE (IIA) 120/240V/SOA BLUE (IIA) (22>...
  • Page 17: Schematic/Wiring Diagram

    Section 8: Wiring Diagram and Schematic WIRING DIAGRAM CIRCUIT CIRCUIT BREAKER BREAKER l,°,,,°v 180V I80V ° ° °_ k/UST (11> (REsD) BLACK (33) B[]NNEBT[]R H[]UBING BI× LU[] ÷ NI]TE: P[]SITIVE BRUSH IS CL[]SEBT T[] BEARING CUST[]MER GROUND LUG...
  • Page 18 Exploded Views and Parts Lists EXPLOD ED VI EW - HAIN UNIT...
  • Page 19 Section 9: Exploded Views and Parts Lists PARTS LIST - MAIN UNIT Item Part # Description B189444GS CRADLE 194150GS KIT,Vibration, Mount 190220GS HOUSING, EngineAdapter ASSY, A Iternator (see page 20_ 194151GS KIT, Hrdwr Mounting Adapter 96796GS WASHER 190274BGS SCREW 187365FGS SCREW 189009GS BRACKET,Muffler...
  • Page 20 Section 9: Exploded Views and Parts Lists ALTERNATOR EXPLODED VIEW PARTS LIST Item Part # Description 186059GS ADAPTER, Mounting, Alternator 190032GS ROTOR 190079AGS STATOR 186060GS RBC, with O-Ring (p/n 189197GS) 86308HGS SCREW 91825GS ASSY,Holder, Rectifier/Brush 66849GS SCREW 22694GS RECEPTACLE, 6 pin 81917GS PIN, Roll 193428AGS...
  • Page 21 Section 9: Exploded Views and Parts Lists CONTROL PANEL EXPLODED VIEWAND PARTS LIST \\.° Part # Item Description 188914GS COVER, Lid, Control Panel 188889GS CONTROL PANEL,Compact 189167GS CLIP,Hinge Pin Retainer 189182GS SPRING,Hinge, Pin 189166GS PIN, Hinge, Cover, Compact 68759GS OUTLET, 120V,20A, Duplex 18916SGS 84198GS CAP, Breaker,Circuit...
  • Page 22 Section 9: Exploded Views and Parts Lists WHEEL KIT EXPLODEDVIEWAND PARTS LIST Item Part # Description 189715GS ASSY,Handle B1764GS LEG, Mounting 52858GS NUT, Lock 39287GS SCREW 191267HGS AXLE B4966GS WHEEL 191265GS E-RING 22247GS WASHER 42907GS SCREW...
  • Page 23: Notes

    Notes NOTES...
  • Page 24 Reglas de Seguridad TABLA DE CONTENIDOS REGLAS DE SEGURIDAD ReglasDe Seguridad ........ 24-26 Conozca Su Generador ........ para advertir al usuario de un posible riesgo para Este es el simbolo de alerta de seguridad. Sirve Ensamblaje........28-29 su integridad fisica. Siga todos los mensajes de Funcionamiento ........
  • Page 25: Reglasde Seguridad

    Secci6n 1: Reglas de Seguridad PELIGRO ADVERTENCIA Opere el generador SOLAMENTE al aire libre. CUANDO AI_IADA COMBUSTIBLE Mantenga al menos 2 pies de espacio libre alrededor del generador, Apague el generador (posicibn OFF) y d_jelo enfriar al menos por para la adecuada ventilaci6n. 2 minutos antes de remover la tapa de la gasolina.Afloje la tapa NO opere el generador dentro de un edificio o lugar cerrado, incluyendo lentamente para dejar que la presi6n salga del tanque.
  • Page 26 Secci6n 1: Instrucciones de Seguridad PRECAUCION ADVERTENCIA Vea "No sobrecargue su generador" en la p_gina 33. Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el/actricas. ;ENERADOR Conecte las cargas el_ctricas en la posici6n de apagado (OFF), luego Siempre desconecte el alambre de la bujla y col6quelo donde no encienda (ON) para su operaci6n.
  • Page 27: Conozca Su Generador

    Caracteristicas ¥ Mandos CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIOY LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras.
  • Page 28 MONTAJE Instale el Juego de Ruedas E[ iuego de ruedas est_ disefiadopara mejorar el transporte de[ Su generador requiere de ciertos procedimientos de montaie y generador. solo estar_ listo para ser utilizado despu_sde haber[e suministrado servicio con el combustible y aceite recomendados. NOTA: Este Juego de Ruedasno ha sido disefiadopara ser usado en la carretera.
  • Page 29 Secci6n 3: Montaje Coloque un extremo de las pinzas de puntas de aguja en la ANTES DE DARLE ARRANQUE parte inferior del eje y el otro extremo de las pinzas en la MOTOR parte superior del e-ring.Asiente el e-ring cerrando las pinzas.
  • Page 30 Operaci6n DEL GENERADOR OPERANDO EL GENERADOR PRECAUCION Tierra del Sistema El generador dispone de una conexi6n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra del sistema est_ conectada al cable de CA neutro que, a su vez, est_ conectado al Vea "No sobrecargue generador"...
  • Page 31 Secci6n 4: Operaci6n NO CONECTE cargas de 50 Hz al generador. NO SOBRECARGUE EL GENERADOR.Vea "No Sobrecargueel Generador" en la p_gina 33. Juego de Cable de 4 Alambres Parado Del Motor Desconecte todas las cargasel_ctricas de los tomaco- rrientes del panel del generador. NUNCA de arranque o detenga el motor con todos los dispositivos el_ctricos conectados y encendidos.
  • Page 32 Secci6n 4: Operaci6n OPERACI( N DURANTE JUEGO DE CABLES CLIMA FRiO ADAPTADOR DEL GENERADOR Baio ciertas condiciones ambientales (temperaturas pot debajo de El generador est_ equipado con un Juego de Cables del Adaptador los 40-_F [4-_C] y un punto alto Dew), su generador puede del Generador de 25 pies, dise_ado para un circuito neutro a experimentar congelamiento del carburador y/o el sistema de tierra de 240 voltios, 30 Amperios (Figura 13).
  • Page 33 Secci6n 4: Operaci6n NO SOBRECARGUE GENERADOR Conecte y encienda la pr6xima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos4 y 5 para cada carga adicional que usted tenga. Usted debe asegurarse que su generador puede proveer el suficiente vataje calificado (cuando est_ funcionando) y de carga NUNCA aSadamgs cargas sobre la capacidad del generador.
  • Page 34: Mantenimiento

    Mantenimiento RECOMENDACIONES Puede usar aire a baja presi6n (que no exceda los 25 psi) para eliminar la suciedad. Inspeccione las ranuras para aire de GENERALES enfriamiento y la apertura del generadon Estas aperturas deber_n mantenerse limpias y despejadas. MANTENIMIENTO PRECAUCION El propietario I operador es responsable...
  • Page 35: Aimacenamiento

    Almacenamiento Almacenando el Motor ALMACENAMIENTO Consulte e[ manual del propietario del motor para las E[ generador deber_ ser encendido al menos una vez cada siete instruccionesde cbmo preparar adecuadamente el motor para su dfas y deber_ dejarlo funcionar al menos durante 30 minutos. Si aimacenamiento.
  • Page 36: Diagnosticos De Averfas

    Diagnosticos de Averias DIAGNOSlTICOS DE AVERiAS Problemo Action Causa Reposicione el interruptor. El interruptor autom_tico de circuito est_ abierto. Revisey repare. Conexi6n real o defectuosa del juego de cables. No hay corriente alterna, pero el motor funciona. El dispositivo conectado est_ daffado.
  • Page 37: Notas

    Notas NOTAS...
  • Page 38 Notas NOTAS...
  • Page 39 POLJTICA PARA EL PROPIETARIO DE EQUIPOSTROY-BILT® Efectiva desde el Iro de Enero, 2003 GARANTIA LIMITADA "Troy-BiltO es una marca registrada de MTD bajo licencia de Briggs & Stratton Power Products. Briggs & Stratton Power Products reparar_ o sustituir_ sin cargo alguno cualquier componente del equipo** que presente defectos de materiales y/o mano de obra.
  • Page 40 TROY-BILT® O WNER WARRANTY POLICY Effective January I, 2003 LIMITED WARRANTY "Troy-Bitt® is a registered trademark of MTD and is used under license to Briggs & Stratton Power Products. Briggs & Stratton Power Products will repair or replace, free of charge, any part, or parts of the equipment** that are defective in material or workmanship or both.Transportation charges on parts submitted for repair or replacement under this warranty must be borne...

Table of Contents