Download Print this page
Honeywell K1148-X 4/98 Installation Instructions
Honeywell K1148-X 4/98 Installation Instructions

Honeywell K1148-X 4/98 Installation Instructions

Rs-232 interface / serial printer port

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
The hardware in this package provides an RS-232 interface to a Destiny control panel (model Des-
tiny 6100, software version 8.04 or later). The interface can be used to provide 2-way communica-
tion with a personal computer, Remote System Mode with an RS-232 equipped controller, or to send
a real-time log of system events to a serial printer.
RJ-45
1
2
6
Female DB-9 Back view
5
4
9
Figure 2: Signal Lines (Female DB-9 Front view)
Pin
DCE DTE
1
DCD DCD
2
RXD TXD
3
TXD RXD
4
DSR DTR
Figure 3: Signal Lines: Interface RJ-45 connector
Downloaded from - http://www.guardianalarms.net
Wire colors from RJ-45
Bl R G O Bk Y Gy/Wh Br
1 2 3 4 5 6
Install crimp pins in matching
DB-9 locations as shown on
the left.
3
4
5
NOTE: Location 9 on DB-9 is empty.
7
8
9
Figure 1: Connector
3
2
1
8
7
6
7
Pin
DCE DTE
1
DCD DCD
2
RXD TXD
3
TXD RXD
4
DSR DTR
5
GND GND
6
DTR DSR
7
RTS
CTS
8
CTS
RTS
Pin
DCE DTE
5
GND GND
6
DTR DSR
7
RTS
CTS
8
CTS
RTS
RS-232 Interface /
Serial Printer Port
NOTE: Observe the drawing
and the connector used and
verify the color codes are
equivalent.
Serial Printers:
If your serial printer requires a
male 9 or 25 pin connector, you
can get a gender changer at an
electronics store. Destiny 6100
8
panel software supports only
GND, TXD, and RXD control
lines. Some printers require
additional control lines. You
may need to jumper these control
lines in order to use such print-
ers. Consult your printer manual
for further information.
Signal Lines:
Figure 2 shows the configuration
of signal lines in the RJ-45/DB-9
converter when wired as shown
in Figure 1. Pin 1 for the RJ-45
connector (J4) is closest to the
top of the board. Figure 3 shows
the signal lines used in a custom
installation with a DB-9 connec-
tor at J1 on the RS-232 board.
The signal lines listed on the RS-
232 Board pertain to this custom
installation, not to the standard
RJ-45.
K1148-X 4/98

Advertisement

loading

Summary of Contents for Honeywell K1148-X 4/98

  • Page 1: Installation Instructions

    DB-9 connec- tor at J1 on the RS-232 board. The signal lines listed on the RS- 232 Board pertain to this custom installation, not to the standard RJ-45. K1148-X 4/98...
  • Page 2 Br Bl Y G R B k O G y 8 Conductor Cable: Top View Y G R B k 4 Conductor Cable: Top View Figure 2: Connection Cable DTE vs. DCE: The RS-232 interface can operate in either Date Terminal Equipment (DTE) or Data Communication Equipment (DCE) mode.

This manual is also suitable for:

Rs-232Destiny 6100