Safety 1st Hospital's Choise 49531 User Manual

Safety 1st Hospital's Choise 49531 User Manual

Accu-light 1-second ear thermometer
Table of Contents

Advertisement

Available languages

Available languages

6mo
+
+
0m
+
Accu-Light 1-Second
Ear Thermometer
+
6 meses
User Guide
Questions? Comments?
Missing Parts? Contact Us:
www.safety1st.com
Manufactured by Microlife Corp., for:
©2008 Dorel Juvenile Group. All Rights
www.djgusa.com (800) 544-1108
Styles and colors may vary.
Distributed by Dorel Juvenile Group
Columbus, IN 47201-7494
Dorel Distribution Canada,
873 Hodge, St-Laurent,
QC Canada H4N 2B1
04/14/08 4358-3677C
Model 49531
(800) 544-1108
Reserved.
www.safety1st.com
Made in CHINA
2525 State Street,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hospital's Choise 49531 and is the answer not in the manual?

Questions and answers

Alberto
February 21, 2025

Change from Fareinght to Celcius

User image 67b8d42503481
1 comments:
Mr. Anderson
February 21, 2025

To change the temperature from Fahrenheit to Celsius on the Safety 1st Hospital's Choice 49531:
1. Turn off the unit.
2. Press and hold the Activation 1 Button until the temperature display appears.
3. Press and release the Activation Button to switch between Fahrenheit (˚F) and Celsius (˚C).
4. Wait three seconds until the thermometer LCD shows a ready display.

The selected measurement scale will remain set unless changed again.

This answer is automatically generated

Summary of Contents for Safety 1st Hospital's Choise 49531

  • Page 1 Accu-Light 1-Second Ear Thermometer Model 49531 User Guide 6 meses Questions? Comments? Missing Parts? Contact Us: www.safety1st.com (800) 544-1108 Manufactured by Microlife Corp., for: ©2008 Dorel Juvenile Group. All Rights Reserved. www.djgusa.com (800) 544-1108 www.safety1st.com Made in CHINA Styles and colors may vary.
  • Page 2 • ALWAYS supervise your child when using thermometer. About Hospital’s Choice Hospital’s Choice products by Safety 1st are manufactured to all applicable regulations and standards, and tested for compliance to these requirements. Keep this Manual for Future Reference For proper use, read the instruction manual completely before using the Accu-Light 1-Second Ear Thermometer.
  • Page 3: Temperature Measurements Range

    Introduction How Does it Work? The Accu-Light 1-Second Ear Thermometer measures the level of infrared energy given off by the eardrum and surrounding tissues and converts this energy into an oral equivalent temperature. Temperature From The Ear Clinical research has shown that the ear is an ideal site for taking body temperature. The eardrum shares the same blood supply with the hypothalamus, the part of the brain that controls body temperature.
  • Page 4: Memory Function

    Introduction How Does it Work? (continued) To obtain the equivalent of a rectal reading for these children, add 0.5°C (0.9°F) to the ear measurement reading. Consulting with your physician When discussing a person’s fever with your physician, be sure to inform your physician of that person’s reference temperature.
  • Page 5: Parts Names

    Parts Names NOTE: The names of the parts are shown below for your convenience. Probe Tip Accu-light Feature LCD Display with Probe Cap Illumination Feature Mute Button On/Off Button Activation Button ˚F/˚C Switch Battery Access...
  • Page 6 Using Your Thermometer To Take a Measurement: 1. Remove the Protective Cap (Figure 1). NOTE: This is a cover free thermometer. Protective Using a probe cover will give an inaccurate reading. 2. Press and release the On/Off Button. The Accu-light Accu-light illuminates.
  • Page 7: Important Notes

    Using Your Thermometer Important Notes: • For an infant, it is best to have the child laying flat with their head sideways so the ear is facing upwards. For an older child or adult, it is best to stand behind and slightly to the side of the patient.
  • Page 8: To Change Measurement Scale

    To Change the Measurement Scale: NOTE: The Accu-Light 1-Second Ear Thermometer can display temperature measurements in either Fahrenheit or Celsius. The unit will be factory preset to Fahrenheit. Use this procedure to change to Celsius or back to Fahrenheit at any time. 1.
  • Page 9: Battery Caution

    Battery Replacement The Accu-Light 1-Second Ear Thermometer includes two AAA batteries already installed which should provide at least 500 measurements. Approximate battery life is three years. If the Low Battery Display appears, you can take only a few more measurements. Low Battery Dead Battery Battery Displays...
  • Page 10: Troubleshooting

    Troubleshooting Display Meaning Action Low Temperature Display Measured temperature Probe may have been (or High “H”) too low (or high), 3 inserted incorrectly. short beeps are Retake temperature emitted. measurement. Ambient temperature Take the High Ambient Temperature too high (above measurement in Display 104.0˚F or 40.0˚C).
  • Page 11: Technical Specifications

    Technical Specifications Temperature measurement range: 32.0°C – 42.2°C (89.6°F – 108.0°F) Operating temperature range: 5.0˚C - 40.0˚C (41.0˚F - 104.0˚F) Storage temperature range: - -20˚C - 50˚C (4.0˚F - 122.0˚F) • Ear Thermometer meets accuracy requirements established in ASTM Standards E1965-98.
  • Page 12: One (1) Year Limited Warranty

    Warranty ONE (1) YEAR LIMITED WARRANTY Dorel Juvenile Group, Inc. warrants to the original purchaser that this product (Accu-Light 1-Second Ear Thermometer), is free from material and workmanship defects when used under normal conditions for a period of one (1) year from the date of purchase. Should the product contain defects in material or workmanship Dorel Juvenile Group, Inc., will repair or replace the product, at our option, free of charge.
  • Page 13 Thermomètre auriculaire Accu-Light 1-Second 6 meses Modèle 49531 Guide d’utilisation Questions ? Commentaires ? Pièces manquantes ? Contactez-nous : www.safety1st.com (800) 544-1108 Fabriqué par Microlife Corp. POUR: ©2008 Dorel Juvenile Group. All Rights Reserved. www.djgusa.com (800) 544-1108 www.safety1st.com Fabriqué en CHINE.
  • Page 14 • TOUJOURS surveiller votre enfant pendant l'utilisation d'un thermomètre. À propos de Hospital's Choice Les produits Hospital’s Choice de Safety 1st sont fabriqués selon toutes les normes et régulations applicables, et ils sont testés pour leur conformité à ces exigences.
  • Page 15: Mode De Fonctionnement

    Introduction Mode de fonctionnement Le Thermomètre auriculaire Accu-Light 1-Second mesure l'énergie infrarouge émise par la membrane du tympan et par les tissus environnants et la convertit en température orale. Température de l'oreille La recherche clinique montre que l’oreille est un endroit idéal pour prendre la température du corps.
  • Page 16 Introduction Mode de fonctionnement (suite) Pour obtenir l’équivalent d’un relevé rectal pour ces enfants, ajoutez 0,5°C (0,9°F) au relevé de la température auriculaire. Consultez votre médecin Lorsque vous discutez de la fièvre d’une personne avec votre médecin, assurez-vous de lui indiquer sa température de référence.
  • Page 17: Noms Des Pièces

    Noms des pièces NOTE: Les noms des pièces sont indiqués ci-dessous à titre indicatif. Extrémité de la sonde avec voyant Accu-light Affichage ACL Bouchon de avec lumière la sonde Bouton Sourdine (Mute) Bouton On/Off Bouton d'activation – Commutateur ˚C/˚F Piles...
  • Page 18 Utilisation de votre thermomètre Pour prendre un relevé : 1. Retirez le bouchon protecteur (Figure 1). NOTE: Ce thermomètre ne requiert pas Bouchon de couvre-sonde. L'utilisation de couvre- protecteur sonde donnera une lecture inexacte. 2. Appuyez sur le bouton On/Off et Voyant relâchez-le.
  • Page 19: Remarques Importantes

    Utilisation de votre thermomètre Remarques importantes : • Pour un nouveau-né, il est préférable que l’enfant repose à plat, tête de côté de manière à ce que l’oreille soit vers le haut. Pour un enfant plus âgé ou un adulte, il est préférable d’être debout derrière la personne et un peu de côté.
  • Page 20: Entretien Et Nettoyage

    Pour modifier l'échelle de mesure : NOTE: Le Thermomètre auriculaire Accu-Light 1-Second peut afficher la température en degrés Celsius ou Fahrenheit. Il est réglé par défaut sur la lecture en degrés Fahrenheit. Suivez ces étapes pour passer de Celsius à Fahrenheit ou vice versa. 1.
  • Page 21 Remplacement des piles Le Thermomètre auriculaire Accu-Light 1-Second comporte deux piles AAA incluses, qui devraient permettre au moins 500 relevés. La durée approximative des piles est de trois ans. Si l'indicateur de piles faibles apparaît, il ne vous reste que quelques relevés. Piles faibles Piles à...
  • Page 22: Dépannage

    Dépannage Affichage Explication Action Affichage de basse température La température La sonde peut avoir (ou élevée «H») mesurée est trop basse été mal introduite. (ou trop élevée), trois Reprenez la bips courts sont émis. température. La température Prenez le relevé à une Affichage de température ambiante est trop température ambiante...
  • Page 23: Spécifications Techniques

    Spécifications techniques Plage de relevé de température : 32°C – 42,2°C (89,6°F – 108°F) Plage de température de fonctionnement : 5°C– 40°C (41°F – 104°F) Plage de température de rangement : -20ºC – 50ºC (-4ºF – 122ºF) • Le thermomètre auriculaire répond aux exigences en matière d’exactitude établies sous la norme ASTM E1965-98.
  • Page 24: Garantie

    Garantie GARANTIE LIMITEE DE UN AN Dorel Juvenile Group, Inc, (DJG) offre la garantie suivante à l’acheteur initial du Thermomètre auriculaire Accu-Light 1-Second : ce produit est garanti contre tout défaut de matériaux ou de fabrication, si utilisé normalement, pendant une période de un an à partir de la date d'achat initiale.