Pin-Out And Cable Type; Rj45 Connectors; 5-Pin Din Connectors - Network Electronics ASA VikinX D3232 User Manual

32x32 rs-422 data router
Table of Contents

Advertisement

D3232
Rev. 4
4.3.

Pin-out and cable type

4.3.1. RJ45 connectors

On some VikinX devices, the NCB cable can be connected to RJ-45 connectors. The following pin-out is
used:
Pin 1 = Not Connected
Pin 2 = Not Connected
Pin 3 = Not Connected
Pin 4 = data
Pin 5 = data
Pin 6 = Not Connected
Pin 7 = Not Connected
Pin 8 = Not Connected

4.3.2. 5-pin DIN connectors

However, the pin-out of most Network Control Bus ports, including that of the D3232 follows the
standard MIDI specification. A 1:1 cable with 5pin DIN connector is used. The following pin-out is used:
Pin 1 = Not Connected
Pin 2 = shield
Pin 3 = Not Connected
Pin 4 = data
Pin 5 = data
The standard MIDI specification recommends the use of shielded twisted pair cable types for
interconnection between the units.