  • Page 3: Table Of Contents

    Contents Revision history General 1.1. Specifications 1.2. Connection drawing Power connection Connecting the D3232 to your PC 3.1. Selection of router level 3.2. Pin-out of RS-232 connector 3.3. Maximum cable length NCB connection 4.1. Several routers in one system 4.2. Connecting control panels 4.3.
  • Page 4 Product Warranty Materials Declaration and EFUP Materials declaration Environmentally Friendly Use Period (EFUP) Recycling information...
  • Page 5: Revision History

    Revision history Current revision of this document is the uppermost in the table below. Revision Replaces Date Change Description 2007-10-24 New front page and removed old logo. 2007-03-29 Added Materials Declaration and EFUP. 26/03/04 Updated warranty description. 01/04/03 Updated Chapter 6 with diagrams. 02/09/02 Initial Revision...
  • Page 6: General

    D3232 Rev. 4 1. General The D3232 is a 32x32 RS-422 data router that simplifies the installation of any of your systems that requires machine control. All ports (sources and destinations) are coupled according to SMPTE-207M machine control standard. The D3232 is well suited for all demanding routing tasks in studio, broadcast and CCTV applications.
  • Page 7: Power Connection

    D3232 Rev. 4 2. Power connection Do not connect mains to the desktop power supply before connecting the power supply to the router. Connect the DB9 female connector from the desktop power supply to the main unit. Tighten the screws to assure a proper contact.
  • Page 8: Connecting The D3232 To Your Pc

    D3232 Rev. 4 3. Connecting the D3232 to your PC For connection to a PC with THOR Router Management System, the RS-232 interface is used. The RS-232 port on all VikinX devices uses the standard DCE pin-out, see pin-out table in Chapter 4.3. A standard modem cable can be used for connecting the router to the PCs serial port.
  • Page 9: Ncb Connection

    D3232 Rev. 4 4. NCB connection Via the Network Control Bus system several routers and control panels can be interconnected. The standard MIDI interface is used on all NCB control ports. The D3232 router utilises 5-PIN DIN connectors for connecting to the NCB. This means that when you connect your D3232 router to other VikinX devices, with RJ45 connectors, an RJ45 to 5-pin DIN interface is necessary.
  • Page 10: Pin-Out And Cable Type

    D3232 Rev. 4 4.3. Pin-out and cable type 4.3.1. RJ45 connectors On some VikinX devices, the NCB cable can be connected to RJ-45 connectors. The following pin-out is used: Pin 1 = Not Connected Pin 2 = Not Connected Pin 3 = Not Connected Pin 4 = data Pin 5 = data Pin 6 = Not Connected...
  • Page 11: Rj45 To 5-Pin Din Converter

    D3232 Rev. 4 4.3.3. RJ45 to 5-pin DIN converter In configurations that include both devices with RJ45 connectors, and devices with 5-pin DIN connectors, an RJ45 to 5-pin DIN converter may be used to complete the control loop. This converter holds both connector types, and may work both ways, thus from RJ45 to 5-pin DIN, as well as from 5-pin DIN to RJ45.
  • Page 12 D3232 Rev. 4 o SDI + AES/EBU + CP for digital system on Level 2 o RS-422 Data + CP for data on Level 3 o Universal Control Panel to control all devices above, with user configurable default level. Pay attention to the figure below, in order to achieve full controllability of all devices in the loop. •...
  • Page 13: Router Configuration

    D3232 Rev. 4 5. Router configuration Router level Switches 1 - 4 on the configuration switch set the router’s level for communication with the VikinX.THOR - Router Management System, and other units in the NCB system. The panels on the NCB dedicated to operate with the router must be configured to the same level as that router.
  • Page 14: Router Orientation

    D3232 Rev. 4 Router orientation There is always a bi-directional connection between an S-port and a D-port when a connection is made. There is therefore an output on both the S-port and the D-port. A Status Request of the router will normally (with DIP-SW 6 down) give the status of the Destinations ports from 1 to 32, i.e.
  • Page 15: Connecting Rs-422 Signals To The D3232

    D3232 Rev. 4 6. Connecting RS-422 signals to the D3232 All ports (sources and destinations) on the D3232 are coupled in accordance to the SMPTE-207M standard. All RS-422 connectors used on the router are female types DB9. Sources There are 32 female D-SUB-9 connectors marked S-1 to S-32. The "S" indicates "Sources". These are intended for direct (one-to-one) connections to Controlling equipment, and they are therefore assigned according to SMPTE207M Tributary: Pin 3:...
  • Page 16 D3232 Rev. 4 Destinations There are 32 female D-SUB-9 connectors marked D-1 to D-32. The "D" indicates "Destinations". These are intended for direct (one-to-one) connections to Controlled equipment, and they are therefore assigned according to SMPTE207M Bus Controller: Pin 7: Pin 2: Pin 4,6: Pin 8:...
  • Page 17: Control And Connection Of Vikinx Systems, Interface Protocol

    D3232 Rev. 4 7. Control and connection of VikinX systems, interface protocol 7.1. Important notes regarding the VikinX Control Protocol 7.1.1. Binary Code The strings shown on the next pages are in binary coded format. Please be aware of the fact that any terminal program you may use to control a VikinX unit from a PC must be able to generate hexadecimal characters.
  • Page 18: Example: A Single Unit With No Ncb Connected

    D3232 Rev. 4 7.2.1. Example: A single unit with no NCB connected Messages sent to the RS232 of a single unit will be returned once no matter what address or input/output number the message has, unless it is a matrix which recognizes one of the conditions a) or b) above. 7.2.2.
  • Page 19: Commands

    D3232 Rev. 4 7.5. Commands 7.5.1. Audio crosspoint set Only for use with Audio routers. Command for setting of crosspoints: 1001nnnn 0kkk kkkk 0vvv vvvv nnnn is the matrix address from 0 up to 15 (Corresponding level 1 to 16, respectively). kkk kkkk is the output that shall be controlled.
  • Page 20: General Environmental Requirements For Vikinx Equipment

    D3232 Rev. 4 General Environmental Requirements for VikinX Equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: • Operating room temperature range 0°C to 45°C • Operating relative humidity range up to 90% (non-condensing) 2.
  • Page 21: Product Warranty

    D3232 Rev. 4 Product Warranty The warranty terms and conditions for the D3232 follow the General Sales Conditions by Network Electronics ASA. These conditions are available on the company web site of Network Electronics ASA: www.network-electronics.com...
  • Page 22: Materials Declaration And Efup

    D3232 Rev. 4 Materials Declaration and EFUP Materials declaration For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the Control of Pollution by Electronic Information Products”. In the first stage of this legislation, content of six hazardous materials has to be declared.
  • Page 23 D3232 Rev. 4 • Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. • All major parts are marked or labelled to show their material content. • Depending on the date of manufacture, this product may contain lead in solder. •...

Table of Contents