• AF-2 fan: Two rigging options exist. Either:
3. Clamp the fan to a truss or similar support.
4. Loop a safety wire that can hold at least 10 times the weight of the
5. Loosen the swivel locks and tilt the fan to the desired angle. Turn the
Placing on a horizontal surface
If an AF-1 MkII or AF-2 fan is to be placed on a horizontal surface:
• Ensure that the surface is level, stable and capable of supporting at
least ten times the weight of the machine.
• Secure the machine so that it cannot slide or fall, even if air pressure
during full speed operation and vibration are present.
• Eliminate any risk of accidental contact.
10
a) Bolt two rigging clamps to two Martin standard omega brackets
(P/N 91602001) using grade 8.8 (minimum) M12 bolts and lock
nuts, or as recommended by the clamp manufacturer. Fasten the
two omega brackets to the flying bracket or touring frame. This
option allows the fan to be flown in line with or at 90° to a truss.
or:
b) Bolt one rigging clamp to one Martin 250-300 wide omega
bracket (P/N 91602000). Fasten the wide omega bracket to the
flying bracket or touring frame. This option allows the fan to be
flown at any angle relative to the truss.
Martin standard omega
bracket: P/N 91602001
machine through/over the support and through the flying bracket or
touring frame.
swivel locks clockwise to tighten. Check that fan, hardware and safety
attachment are secure before applying power.