Drolet CLASSIC EPA WOOD STOVE Owner's Manual page 10

Table of Contents

Advertisement

Floor protector
If the stove is to be installed on top of a combustible floor, it must be guarded by a non combustible material
as shown on figure 1.3 (see the dotted line area).
G
H
M
N
*Steel with a minimum thickness of 0.015'' (0.38 mm) or ceramic tiles sealed together with grout. No
protection is required if the unit is installed on a non-combustible floor (ex: concrete).
Note 1 : The floor protection at the back of the stove is limited to the stove's required clearance if such
clearance is smaller than 8 inches (203 mm).
Note 2 : Only required under the horizontal section of the connector. Must exceed each side of the
connector by at least 2 inches (51 mm).
Reduced clearances using shielding
You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the
stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-
combustible sheet or a masonry wall.
Clearances of not less than 1" (25 mm) and not more than 3" (76 mm) between the bottom of the shield and
the floor and not less than 3" (76 mm) between the top of the shield and the ceiling must be respected to allow
vertical air circulation behind the shield. The shield must extend 20" (500 mm) above the stove top and 18"
(450mm) to each side of the stove (see graphic 1).
Following the installation of such a heat radiation shield, the clearances mentioned on the stove certification
plate may be reduced as stated in the following table.
CANADA
8'' (205 mm) – Note 1
8'' (205 mm)
18'' (460 mm)
I
From door opening
N/A (USA only)
J
8'' (205 mm)
N/A (USA only)
FLOOR PROTECTOR*
N/A (Canada only)
N/A (Canada only)
16'' (410 mm)
From door opening
N/A (Canada only)
USA
8'' (205 mm)
Note 2
9