Troubleshooting

If you experience low output, pump noise or no output at all, unplug immediately and do the following:
1)
Check fluid level, the external fuse, remote connection and main power supply. If all appear to
be OK, plug the unit in again.
2)
If snow does not come out after holding the remote control button for 30 seconds, check the
hose attached to the tank to make sure there is fluid going through the hose.
3)
If you are unable to determine the cause of the problem, do not simply continue to push the
remote control button as this may damage the unit. Contact CHAUVET Technical Support at the
location below.

Technical Support

Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): tech@chauvetlighting.com
Telephone: (954) 929-1115 - (Press 4)
Fax: (954) 929-5560 - (Attention: Service)
Website: http://www.chauvetlighting.com
5. A
PPENDIX

General Maintenance

Warning:
If your snow machine will be stored for more than 30 days, it must be purged before being
stored. Failure to do so will void your warranty. To purge your fogger or snow machine, follow
the instructions below.
Your snow machine should be purged every 15 days to avoid build-up of particles in the system. To
purge your snow machine, follow these instructions:
1)
Drain the unit of all fluid.
2)
Fill the tank with distilled water.
3)
Run the unit until all the distilled water is consumed (i.e. until the tank is dry).
4)
Store your unit.
5)
It is highly recommended that you run your unit with its respective fluid and then purge the
system AT LEAST once every 30 days.