Download Print this page

Smeg GW3060 User Manual page 40

Glassware washer
Hide thumbs Also See for GW3060:

Advertisement

56
DOORLOCK 1 FAILURE
58
DRYING 1 FAILURE (NOT APPLICABLE)
60
DRYING 1 SAFETY SWITCH ON
(NOT APPLICABLE)
62
HEATING THERMOSTAT ON
63
BLOWER 1 FAILED(NOT APPLICABLE)
65
FAN SENSOR 1 FAILED
(NOT APPLICABLE)
67
COOLING FAILED -WARNING: HIGH
TEMP(NOT APPLICABLE)
68
TANK 1 EMPTY
69
TANK 2 EMPTY
70
TANK 3 EMPTY
71
TANK 4 EMPTY
73
ARCHIVE ERROR
74
CHAMBER LEAKAGE
75
LACK OF SALT
76
BOILER SAFETY SWITCH ON
(NOT APPLICABLE)
77
TEMPERATURE > 45°C
78
RECOVERY FAILED
79
PROGRAM NOT CONGRUENT
80
WARM WATER FLOWMETER FAILURE
81
DEMI WATER FLOWMETER FAILURE
82
SYSTEM FAILURE SOL.1
84
OVERTEMPERATURE TA1
91
ARCHIVE FULL
92
CHANGE FILTER(NOT APPLICABLE)
93
MAINTENANCE REQUEST
Versione 09/11/2009
Manual GW3060 - User
40
Make sure that the door is properly
closed before beginning a cycle. Call
the Technical Assistance Service if the
fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Press the 2nd button located on the
bottom of the drawer (see §17.1) and
repeat the cycle. If the fault persists,
call the Technical Assistance Service.
Press the 1st button located on the
bottom of the bottom drawer (see
§17.1) and repeat the cycle. If the fault
persists, call the Technical Assistance
Service.
Call the Technical Assistance Service
Call the Technical Assistance Service
Call the Technical Assistance Service
Fill the relative can.
Fill the relative can.
Fill the relative can.
Fill the relative can.
Error inside the microprocessor.
Call the Technical Assistance Service
if the fault persists.
Call the Technical Assistance Service
Fill the softener's salt reservoir (plug
in tub).
If it is present, try to reactivate the
thermostat and repeat the cycle. If the
problem persists, call the Technical
Assistance Service.
Appears (if option selected) if the
temperature of the water entering in
the first phase exceeds 45°C.
Error inside the microprocessor.
Call the Technical Assistance Service
if the fault persists.
Incongruent program error. Check the
settings of the required cycle.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Download the data from the archive.
Air filter replacement. Call the
Technical Assistance Service
Air filter replacement. Call the
Technical Assistance Service

Advertisement

loading