Download Print this page

Smeg GW3060 User Manual page 39

Glassware washer
Hide thumbs Also See for GW3060:

Advertisement

FAILURE
30
SAFETY CHAMBER LEVEL EXCEEDED
31
SAFETY LEVEL FAILED
32
SUMP FULL
33
LACK
CONDENSER
34
CONDENSER DRAINAGE FAILED
35
CONDENSER LEVEL SWITCH FAILED
36
CONDENSER DRAINING PUMP FAILED
37
NOT REACHED TARGET DRAINAGE AT
T=
38
COOLED DRAINAGE FAILED
41
DETERGENT 1 INFLOW FAILED
(flowmeter nr.1 optional)
42
DETERGENT 2 INFLOW FAILED
(flowmeter nr.2 optional)
43
DETERGENT 3 INFLOW FAILED
(flowmeter nr.3 optional)
44
DETERGENT 4 INFLOW FAILED
(flowmeter nr.4 optional)
46
PUMP 1 TUBE CLOGGED
47
PUMP 2 TUBE CLOGGED
48
PUMP 3 TUBE CLOGGED
49
PUMP 4 TUBE CLOGGED
51
VERIFIY CONNECTIONS
FLOWMETER/PUMPS
52
DOOR 1 ELECTRICALLY OPEN
54
DOOR 1 MECHANICALLY OPEN
Versione 09/11/2009
Manual GW3060 - User
OF
WATER
IN
39
positioned as indicated in the manual.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Make a Reset cycle. Repeat the cycle.
Call the Technical Assistance Service
if the fault persists.
Check the water supply (cock
THE
STEAM
open/closed, water pressure,
connection pipe, etc.)
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Make sure that the drain pipe is
positioned as indicated in the manual.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Make sure that the suction tubes of can
P1 are in a good condition and not
squashed. Repeat the cycle. Call the
Technical Assistance Service if the
fault persists.
Make sure that the suction tubes of can
P2 are in a good condition and not
squashed. Repeat the cycle. Call the
Technical Assistance Service if the
fault persists.
Make sure that the suction tubes of can
P3 are in a good condition and not
squashed. Repeat the cycle. Call the
Technical Assistance Service if the
fault persists.
Make sure that the suction tubes of can
P4 are in a good condition and not
squashed. Repeat the cycle. Call the
Technical Assistance Service if the
fault persists.
See 41
See 42
See 43
See 44
Repeat the cycle. Call the Technical
Assistance Service if the fault persists.
Make sure that the door is properly
closed before beginning a cycle. Call
the Technical Assistance Service if the
fault persists.
Make sure that the door is properly
closed before beginning a cycle. Call
the Technical Assistance Service if the
fault persists.

Advertisement