Legacy OS Redirection
On Legacy OS, the Number of Rows and Columns supported redirection
3.3.11.2
e Redirection Settings
Figure 3.16 Console Redirection Settings
Terminal Type
VT-UTF8 is the preferred terminal type for out-of-band management. The next best
choice is VT100+ and then VT100. See above, in Console Redirection Settings page,
for more Help with Terminal Type/Emulation.
Bits per second
Select the serial port transmission speed. The speed must be matched on the other
side. Long or noisy lines may require lower speeds.
Flow Control
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a 'stop' signal can be sent to stop the data flow. Once the
buffers are empty, a 'start' signal can be sent to re-start the flow. Hardware flow con-
trol uses two wires to send start/stop signals.