9. Error data display Mode
Step No.
Setting Method
Step 1
Test mode STOP state
Step 2
BASS button
Step 3
AUTO menu
Step 4
SKIP UP button x 8times
(Or SKIP DOWN button x 2 times)
Step 5
Error data indication menu
Step 6
PLAY button
Step 7
Indication of error data 0
Step 8
SKIP UP button
Step 9
Indication of error data 1
Step 10
SKIP UP button
Step 11
Indication of error data 2
Step 12
SKIP UP button
Step 13
Indication of error data 3
Step 14
SKIP UP button
Step 15
Indication of error data 4
Step 16
SKIP UP button
Step 17
Indication of error data 5
Step 18
SKIP UP button
Step 19
Indication of error data 6
Step 20
SKIP UP button
Step 21
Indication of error data 7
Step 22
SKIP UP button
Step 23
Indication of error data 8
Step 24
SKIP UP button
Step 25
Indication of error data 9
Step 26
STOP button
Step 27
Test mode STOP state
• Reversing when SKIP DOWN button is pressed
• When the STOP button is pressed while the error data indication menu appears or during error data indication, the mode changes to the
TEST mode stop state.
• Error data 0 is the latest error.
• Error which occurred in the TEST mode is also stored in the memory.
• When the DISP button is pressed while the error data indication menu appears, the error data is initialized. [ C L E A R _ ]
: Error Code
Jitter checking method
Tr: 2SC1815
IC701 20 PIN
2SC1740
+3V
100 ohm
TP145
(EFM)
560 ohms
-3V
TP141
(GND)
IC101
7 PIN
After automatic adjustment is performed in the AUTO mode (low
reflection MD disc use TEST mode), jitter must be less than 32 ns.
Display
[
T E S T
[
A U T O
[ E
D A T A
[ E 0
[ E 1
[ E 2
[ E 3
[ E 4
[ E 5
[ E 6
[ E 7
[ E 8
[ E 9
[
T E S T
JITTER MATER
0.33
IC701 17 PIN
Figure 15
MD-MS200W/MD-MS200/MD-MS200H
Error data list
Error Code
]
11
Automatic adjustment
adjustment judgment NG during adjustment retry in TG, FG
adjustment.
]
12
Automatic adjustment
13
Automatic adjustment
adjustment
]
16
Automatic adjustment
(TG, TB measurement value does not change.)
17
Automatic adjustment
]
21
Focus setting disabled
23
Track search time-over
]
32
P-TOC read disabled
42
U-TOC read disabled
]
44
U-TOC write disabled
52
Music data write disabled
]
71
Pickup position initialization error (Inner switch ON failure)
72
EEPROM read error
]
73
Record head drive disabled (EJECT operation)
82
Overvoltage detection
]
91
TEMP over
]
]
]
]
]
– 15 –
Contents
Gain maximum or error
Out of allowable range
Servo retry error (4 times) during
TZC error in TG, TB adjustment
TEO, FEO allowable range error